2.4.3 Output

n

ote

!

It is not possible to connect an external voltage to the converter output terminals! It is not

even possible to disconnect the motor from the device output while the drive is active.

In normal cases no leveling choke is necessary. It must be taken into account, anyway, that some motor produc-

ers prescribe such a choke according to the type of the motor used. In this case it must inserted on the motor

cable.
The stated currents refer to the continuative operation with an ambient temperatrue of 104°F (40° C).

Output current

Armature circuit

Table 2.4.3.1: Output currents

American

European

Field converter

Armature current

Armature current

(Term. C1 / D1)

(Terminals C / D)

(Terminals C / D)

Continuous curr.

*Max. current

Continuous curr.

*Max. current

Continuous curr.

with Ambient

(with overload)

with Ambient

(with overload)

with Ambient

temp @ 104°F

**

temp @ 104°F

**

temp @ 104°F

6KDV3017...

17 A

34 A

6KDV3020...

20 A

40 A

10 A

6KDV3035...

35 A

70 A

6KDV3040...

40 A

80 A

10 A

6KDV3056...

56 A

112 A

6KDV3070...

70 A

140 A

10 A

6KDV3088...

88 A

172 A

6KDV3110...

110 A

220 A

14 A

6KDV3112...

112 A

224 A

6KDV3140...

140 A

280 A

14 A

6KDV3148...

148 A

296 A

6KDV3185...

185 A

370 A

14 A

6KDV3224...

224 A

448 A

6KDV3280...

280 A

560 A

20 A

6KDV3280...

280 A

560 A

6KDV3350...

350 A

700 A

20 A

6KDV3336...

336 A

672 A

6KDV3420...

420 A

840 A

20 A

6KDV3400...

400 A

800 A

6KDV3500...

500 A

1000 A

20 A

6KDV3450...

450 A

900 A

6KDV3650...

650 A

1300 A

20 A

6KDV3560...

560 A

1120 A

6KDV3770...

770 A

1540 A

25 A

6KDV3800...

800 A

1600 A

6KDV310HQ2...

1000 A

2000 A

25 A

6KDV3850...

850 A

1700A

6KDV310HQ4...

1050 A

2100 A

25 A

GD0050g

*

Current reduction for higher temperatures, see section 3.1, “Permissible ambient conditions”.

** The overload size and duration depend on the overload cycle, see section 6.14.5, “Overload control”

As for sizes above 850 / 1050 A (American / European) see Appendix A (GEI-100332C).

n

ote

!

The field motor current can sometimes be very small compared with rated field current of

the converter. In order to provide regulation during Voltage control of the motor, follow the

described instructions to change the Flux current max of the converter. In this case the Nom

field scale parameter must be set with the new rated field current value.