Figure 6.11.4.1: speed feedback, Motor – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 178

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

50

Speed

Index Storing

Motor

A

H

Tacho

+

-

T

ach

generator

CEMF

Armature

Fbk Bypass

Encode

r

1

Sinusoidal

6

5

1

8

4

3

A+

A-

B+

B-

C+

C-

0V

5V

XE1 connector

9

7

Encode

r

1

Digital

6

5

1

8

4

3

A+

A-

B+

B-

C+

C-

0V

24

XE2 connector

2

7

Enable ind store

Disabled

Encoder 2 pulses

1024

Refresh enc 2

Disabled

Encoder 1 pulses

1024

Refresh enc 1

Disabled

Speed fbk sel

Armature

Speed fbk sel

Encoder 1

Speed fbk sel

Encoder 2

Speed fbk sel

Tacho

Enc 1 speed

PD output PID

Encoder 1 state

Encoder 2 state

Speed offset

0

Tacho scale

1

Actual spd (d)

Max. out voltage

500 V

Output voltage

Enable fbk bypass

Disabled

Figure 6.11.4.1: Speed feedback

Motor max speed

Max motor speed. It is used to convert tach and armature feedback values in rpm. In case

of speed feedback from tachogenerator it is used to convert the tach voltage in an rpm

value. In case of armature voltage feedback Max out voltage parameter is considered

equivalent to Motor max speed.

Speed fbk sel

Select which feedback has to be used.

Encoder 1

The sinusoidal encoder connected th the XE1 connector is used.

Encoder 2

The digital encoder connected to the XE2 connector is used

(standard).

Tacho

The analog tachogenerator connected to the terminals + and - is used.

Armature

The internal measurement of the armature voltage is used. No

external connection is required.

Enable fbk contr

Enable of the control for the speed feedback.

Enabled

Enabled control

Disabled

Disabled control

This function controls the speed feedback, where a comparison between the armature

voltage and the speed value read by the encoder or by the tachometer is made. When an

excursion higher of the value set via Speed fbk error is signaled, the failure message

“Speed fbk loss” appears. This function is automatically disabled when the armature

feedback has been selected. (Speed fbk sel = Armature).

Advertising