DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

51

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Flux reg mode

(Field reg mode)

Constant current

Voltage control

(Field weakening)

External control (OFF)

469

U16

0

2

Const.

current

0

Const.

current

0

ü

R/Z

0

1

2

-

-

Hold off time [ms]

470

U16

0

100

0

0

ü

R/W

-

-

Latch

ON

OFF

471

U16

0

1

ON

ON

ü

R/Z

1

0

-

-

Ok relay open

ON

OFF

472

I16

0

1

ON

ON

ü

R/W

1

0

-

-

Activity

Ignore

Warning

Disable drive

473

U16

0

2

Disable

drive

Disable

drive

ü

R/Z

0

1

2

-

-

Restart time [ms]

474

U16

0

10000

0

0

ü

R/W

-

-

Hold off time [ms]

475

U16

0

10000

0

0

ü

R/W

-

-

Ok relay open

ON

OFF

477

I16

0

1

ON

ON

ü

R/W

1

0

-

-

Activity

Warning

Disable drive

478

U16

1

2

Disable

drive

Disable

drive

ü

R/Z

1

2

-

-

Hold off time [ms]

480

U16

0

10000

8

8

ü

R/W

-

-

Undervolt thr [V]

481

U16

0

1000

230

230

ü

R/W

-

-

Hold off time [ms]

482

U16

0

10000

0

0

ü

R/W

-

-

Restart time [ms]

483

U16

0

10000

0

0

ü

R/W

-

-

Source

484

U16

0

65535

0

0

ü

R/W

-

-

Destination

485

U16

0

65535

0

0

ü

R/W

-

-

Mul gain

486

Float

-10000

+10000

1

1

ü

R/W

-

-

Div gain

487

Float

-10000

+10000

1

1

ü

R/W

-

-

Input max

488

Float

-231

231-1

0

0

ü

R/W

-

-

Input min

489

Float

-231

231-1

0

0

ü

R/W

-

-

Input offset

490

Float

-231

231-1

0

0

ü

R/W

-

-

Output offset

491

Float

-231

231-1

0

0

ü

R/W

-

-

Inp absolute

OFF

ON

492

U16

0

1

OFF

OFF

ü

R/W

0

1

-

-

Voltage P [%]

493

Float

0.00

100.00

30.00

30.00

ü

R/W

-

-

Voltage I [%]

494

Float

0.00

100.00

40.00

40.00

ü

R/W

-

-

Voltage P base [f%/V]

495

Float

0.0100

S

S

S

ü

R/Z

-

-

Voltage I base [f%/V·ms]

496

Float

0.01

S

S

S

ü

R/Z

-

-

Enable flux reg

(Enable field reg)

ON (Enabled)

OFF (Disabled)

497

U16

0

1

Enabled

Enabled

ü

R/W

1

0

ID

H

L

-

Enable flux weak

(En min field cmd)

ON (Enabled)

OFF (Disabled)

498

U16

0

1

1

1

ü

R/W

1

0

ID

H

L

-

Speed-0 f weak

(Field economy)

Enabled

Disabled

499

U16

0

1

0

0

ü

R/W

1

0

-

-

Flux reference [%]

(Field reference [%])

500

Float*

0.0

100.0

-

-

ü

R

QA

-