GEI-100332Ga
——— FUNCTION DESCRIPTION ———
6
160
Analog output 1 / Select output 1= PID output
(with Real FF PID = 10000 count, Analog output 1 = 10V).
n
ote
:
If it is necessary, a system with the integral regulation enabled, with feed-forward = 0, and
the need to apply tension of the system with null error also when the machine is stopped,
please refer to the paragraph “Generic PID”.