——— PARAMETER LISTS ———

10

4

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

START UP \ Limits

T current lim [%]

7

U16

0

200

150

150

ü

R/W

IA

R/W

Flux current min [%]

(Min field curr [%])

468

U16

0

P467

5

5

ü

R/W

-

----

Flux current max [%]

(Max field curr [%])

467

U16

P468

100

100

100

ü

R/W

-

R/W

Speed min amount [FF]

1

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max amount [FF]

2

U32

0

232-1

5000

5000

ü

R/Z

-

-

START UP \ Speed feedback

Speed fbk sel

Encoder 1

Encoder 2

Tacho

Armature

414

U16

0

3

1

1

ü

R/Z

0

1

2

3

-

R

Tacho scale

562

Float

0.90

3.00

1.00

1.00

ü

R/W

-

-

Speed offset

563

Float

-20.00

+20.00

0.00

0.00

ü

R/W

-

-

Encoder 2 pulses

169

Float *

600

9999

1024

1024

ü

R/Z

-

R

Enable fbk contr
Enabled

Disabled

457

U16

0

1

Disabled

0

Disabled

0

ü

R/Z

1

0

-

-

Refresh enc 2

(Enc 2 loss detect)

Enabled

Disabled

652

U16

0

1

0

0

ü

R/W

1

0

-

-

START UP \ Alarms

Undervolt thr [V]

481

U16

0

1000

230

230

ü

R/W

-

-

Overcurrent thr [%]

584

U16

0

200

160

160

ü

R/W

-

-

START UP \ Overload contr

Enable overload

Enabled

Disabled

309

I16

0

1

Enabled

Disabled

ü

R/Z

1

0

-

-

Overload mode

Curr limited

Curr not limited

I2t Motor

I2t Drive

I2t Motor & Drv

318

U16

0

4

I2t Motor

Curr

limited

ü

R/W

0

1

2

3

4

-

-

Overload current [%]

312

U16

P313

200

150

100

ü

R/W

-

-

Base current [%]

313

U16

0

P312

< 100

100

80

ü

R/W

-

-

Overload time [s]

310

U16

0

65535

60

30

ü

R/W

-

-

Motor ovrld preal.

1289

U16

0

1

-

-

ü

R

-

-

Motor I2t accum

655

Float

0,00

100,00

-

-

ü

R

-

-

Drive ovrld preal.

1438

U16

0

1

-

-

ü

R

-

-

Drive I2t accum

1439

FLOAT

0,00

100,00

-

-

ü

R

-

-

Pause time [s]

311

U16

0

65535

540

300

ü

R/W

-

-

Overld available

Overload not possible

Overload possible

406

U16

0

1

-

-

-

R

0

1

QD

L

H

R

0

1

Overload state

Current limit value

Current > limit value

407

U16

0

1

-

-

-

R

0

1

QD

L

H

R

0

1

START UP \ Analog inputs \ Analog input 1

Select input 1

70

U16

0

32

Ramp ref Ramp ref

ü

R/Z

-

-

1 (4)

1 (4)

OFF

0

Jog reference

1

Speed ref 1

2

Speed ref 2

3

Advertising