3 - installation guidelines, 1 permissible ambient condition – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 41

Advertising
background image

DV-300 Adjustable Speed Drives

——— INSTALLATION GUIDELINES ———

3

1

3 - insTallaTion Guidelines

3.1 pERMISSIBLE AMBIENT CONDITION

Protection degree:

IP 20 at operating temperatures of 32-131° F (0 ... 55° C).

UL enclosure type 1.

(American size) The converter must be installed in a pollution degree

2 environment.

Altitude:

Up to 3300 feet (1000 m) above sea level; higher altitudes a current

reduction of 1.2 % for every 330 feet (100 m) of additional altitude.

Temperature :

Operation

Ambient temperature = 32-131° F (0 ... 55° C).

Over 104° F (40 °C): current reduction of 1.25 % for every 1.8 ° F over

104° F (1 °C over 40 °C) better than the 3K3 class per EN 50178)

Storage

Ambient temperature = -13° F ... 131° F (-25 ... +55° C)

(1K4 class as per EN 50178)

Ambient temperature = -4° F ... 131° F (-20 ... +55° C) for devices

with keypad (type DV-300)

Transport

Ambient temperature = -13° F ... 131° F (-25 ... +55° C)

(2K3 class as per EN 50178)

Ambient temperature = -4° F ... 140° F (-20 ... +60° C) for devices with

keypad (type DV-300)

Air humidity:

Operation

5% up to 85%, 1 g/m

3

up to 25 g/m

3

without moisture condensation or icing

(3K3 class as per EN 50178)

Storage

5% up to 95%, 1 g/m

3

up to 29 g/m

3

(1K3 class as per EN 50178)

Transport

95% 1)

60 g/m 2)

A light condensation of moisture may occur for a short time

occasionally when the device is not in operation.

(2K3 class as per EN 50178)

Air pressure:

Operation

From 86 kPa up to 106 kPa ( 3K3 class per EN 50178 )

Storage

From 86 kPa up to 106 kPa ( 1K4 class per EN 50178 )

Transport

From 70 kPa up to 106 kPa ( 2K3 class per EN 50178 )

1)

Greatest relative air humidity occurs with the temperature 104° F (40° C) or if the temperature of the device is brought immedi-
ately from -13° F ... 86° F (-25° C to +30° C).

2)

Greatest absolute air humidity if the device is brought immediately from 158° F ... 59° F (70° C to +15° C).