1 analog ouputs – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 193

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

65

When other digital inputs/outputs and/or analog outputs are required, together with the already existing ones,

the TBO option card has to be used, which is inserted on the converter regulation card. A converter card can

also be mounted (see figure):

- with TBO “B” (6KCV300TBO) option card:

Option “B”:

2 Analog outputs (3 and 4) with common reference point

4 Digital outputs (5 ...8) with common reference point and common voltage supply

4 Digital inputs (5...8) with common reference point.

n

ote

!

If parameters are assigned to particular terminals, the parameter value (e.g. speed reference

value) can only be entered via this terminal and not via the keypad or bus.

6.12.1 Analog Ouputs

I/O CONFIG

Analog outputs

Analog output 1

[66]

Select output 1

[62]

Scale output 1

Analog output 2

[67]

Select output 2

[63]

Scale output 2

Analog output 3

[68]

Select output 3

[64]

Scale output 3

Analog output 4

[69]

Select output 4

[65]

Scale output 4

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Select output 1

66

0

94

Actual speed (8)

Actual speed (8)

Scale output 1

62

Float

-10.000

+10.000

0.000

0.000

Select output 2

67

0

94

Motor current (16)

Motor current (16)

Scale output 2

63

-10.000 +10000

0.000

0.000

Select output 3

68

0

94

Flux

-27

Flux

-27

*

Scale output 3

64

-10.000 +10000

0.000

0.000

Select output 4

69

0

94

Output voltage (20)

Output voltage (20)

*

Scale output 4

65

-10.000 +10000

0.000

0.000

*

6KCV300TBO option card (TBO “B”) has to be installed.

Select output XX

Selection of the parameter assigned as a variable to the corresponding analog output.

The following assignments are possible:

Advertising