1 general, 2 inputs / outputs, 1 general 6.16.3.2 inputs / outputs – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 266

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

138

6.16.3.1 General

The PID function has been developed for general uses which can include nip-roll, winders, unwinders, pressure

control of pumps and extruders.
A dancer or a load cell can be used as position/tension transducer.
The inputs (with the exception of those concerning the transducers) and the outputs can be configured, they

can be associated to various converter parameters. E.g. the PID output can be sent to the speed or to current

regulator.

The analog inputs/outputs will be sampled/updated to 2ms.
The digital inputs/outputs will be sampled/updated to 8ms.

n

ote

!

PID function in the firmware can not be used when the DGF card is present.

6.16.3.2 Inputs / Outputs

Regulation Inputs/outputs

PID source

Sample parameter of Feed-forward normally programmed on analog input.

PID feed-back

Analog input of position / tension transducer (dancer/load cell).

PID feed-back must be programmed on the analog input 1 (terminals 1-2) because of

the input filter provided.

PID offset 0

Offset analog input added to PID feed-back. Used for the adjustement of the dancer position.

PID target

Parameter associated with the regulator output. Normally, it will be programmed on

the speed reference of the drive.

PID output

Analog output of the regulator. Used to carry on a reference cascade in multidrives systems.

PI central v3 PID

Initial value setting of the integral component of the regulator (corresponds to initial

diameter). It can be programmed on an analog input. E.g. to an ultrasonic transducer

used for the diameter measure of a winder/unwinder.

Input Command (programmable on digital inputs)

Enable PI PID

Enable of the PI (proportional - integral) of the regulator.

Enable PD PID

Enable of the PD (proportional - derivative) of the regulator.

PI integral freeze:

Freezing of the actual value of the integral component of the regulator.

PID offset sel

Offset select, in addition to PID feed-back: L = PID offset 0, H = PID offset 1.

PI central v S0

Used with PI central v S1 to select one of four values for the initial integral level (cor-

responding to initial diameter). Through binary seletion.

PI central v S1

Used with PI central v S0 to select one of four values for the initial integral level (cor-

responding to initial diameter). Through binary seletion.

Diameter calc

Enable of the initial diameter calculation.

Diameter calc st

State of the initial diameter calculation (digital output).