DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

85

0

t

0

t

Actual spd (rpm)

Threshold delay

100 ms

Spd threshold

Spd threshold +

1000 rpm

Spd threshold -

1000 rpm

Set delay

100 ms

Set speed

Set error

100 rpm

Speed ref

Actual spd (rpm)

Figure 6.13.3.1: “Speed threshold” (up) and “Set speed” (down) messages