——— FUNCTION DESCRIPTION ———

6

135

6.16 OpTIONS

6.16.1 Option 1

OPTIONS

Option 1

Menu

Through this menu the assignement of Drive parameters to the virtual digital I/O (MONITOR\Virtual digital

Inp-Out menu) and to the process data channels (PDC) of the field bus can be carried out.
If the bus card is not present you will be prompted (inside the menu) by the message OPT1 not present.
If the used bus card is not up-to-date for this management, you will be prompted (inside the menu) by the mes-

sage OPT1 old version.
For further and detailed information, refer to the bus interface instruction book.

6.16.2 Option 2

OPTIONS

Option 2

Menu

[425]

Enable OPT2

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Menu
Enable OPT2

Enabled (1)

Disabled (0)

425

0

1

Disable

Disable

This menu allows the user access to the parameter set of the 6KCV300DGF option card.

Menu

The menu is active only if the OPT2 card is present (e.g. a 6KCV300DGF card). If the

user tries to enter in the Option 2 menu and the card is not mounted on the device the

message “Not present” is displayed.

For further and detailed information see the instruction book of the optional board.

Enable OPT2

This command can also be given from keypad, when “Bus” through the Control mode

parameter, has been selected.

Default configuration = Disabled.

To change the configuration:

1 - set the new value of Enable OPT2 parameter

2 - store via the Save parameters (BASIC MENU)

3 - switch-off and switch-on the drive