Table 4.10.1.1: AC input choke

Converter

Main three-phase inductance

Rated

choke [mH]

Rated ac

current [A]

Saturation

current [A]

Freq. [Hz]

Model No.

Main 400 V, 3Ph, 50 Hz
6KDV3020Q2A.../Q4E...

1,71

17,2

34,4

50

KLR18CTB

6KDV3040Q2A.../Q4E...

0,855

34,4

68,8

50

KLR45CTB

6KDV3070Q2A.../Q4E...

0,488

60,2

120,4

50

KLR80CTB

6KDV3110Q2A.../Q4E...

0,311

94,6

189,2

50

KLR110CCB

6KDV3140.Q2A.../Q4E...

0,244

120,4

240,8

50

KLR160CCB

6KDV3185Q2A.../Q4E...

0,185

159

318

50

KLR300CCB

6KDV3280Q2A.../Q4E...

0,122

241

482

50

KLR300CCB

6KDV3350Q2A.../Q4E...

0,098

301

602

50

KLR360CCB

6KDV3420Q2A.../Q4E...

0,081

361

722

50

KLR420CCB

6KDV3500Q2A.../Q4E....

0,068

430

860

50

KLR600CCB

6KDV3650Q2A.../Q4E....

0,053

559

1118

50

KLR750CCB

6KDV3770Q2A.../Q4E....

0,044

662

1324

50

KLR750CCB

6KDV310HQ2A.../Q4E....

0,034

860

1720

50

KLR1250C

6KDV310HQ2A.../Q4E...

0,033

903

1806

50

KLR1250C

Main 460 V, 3Ph, 60 Hz
6KDV3017Q2B.../Q4F...

1,933

14,6

29,2

60

KLR18CTB

6KDV3035Q2B.../Q4F...

0,938

30,1

60,2

60

KLR45CTB

6KDV3056Q2B.../Q4F...

0,586

48,2

96,4

60

KLR80CTB

6KDV3088Q2B.../Q4F...

0,373

75,8

151,6

60

KLR110CCB

6KDV3112.Q2B.../Q4F...

0,293

96,4

193

60

KLR160CCB

6KDV3148Q2B.../Q4F...

0,227

127,4

255

60

KLR160CCB

6KDV3224Q2B.../Q4F...

0,146

193

386

60

KLR300CCB

6KDV3280Q2B.../Q4F...

0,117

241

482

60

KLR300CCB

6KDV3336Q2B.../Q4F...

0,098

289

578

60

KLR360CCB

6KDV3400Q2B.../Q4F....

0,082

344

688

60

KLR420CCB

6KDV3450Q2B.../Q4F....

0,073

387

774

60

KLR600CCB

6KDV3560Q2B.../Q4F....

0,058

482

964

60

KLR600CCB

6KDV3800Q2B.../Q4F....

0,041

689

1378

60

KLR1250C

6KDV3850Q2B.../Q4F...

0,038

732

1464

60

KLR1250C

GD0330g

4.10.2 Interference suppression filters

The converters of DV-300 series must be equipped with an external EMI filter in order to reduce the radio-

frequency emissions on the mains line. The filter selection is depending on the drive size and the installation

environment. For this purpose see the “EMC Guidelines”.

In the Guide it is also indicated how to install the cabinet (connection of filter and mains reactors, cable shields,

grounding, etc.), in order to make it EMC compliant according the EMC Directive 89/336/EEC.

The document describes the present situation concerning the EMC standards and the compliance tests made on

the GE drives.

Advertising