GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 430

Advertising
background image

GEI-100332Ga

——— PARAMETER LISTS ———

10

36

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

DRIVECOM \ Speed amount

Speed min amount [FF]

1

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max amount [FF]

2

U32

0

232-1

5000

5000

ü

R/Z

-

-

DRIVECOM \ Speed min/max

Speed min pos [FF]

5

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max pos [FF]

3

U32

0

232-1

5000

5000

ü

R/Z

-

-

Speed min neg [FF]

6

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max neg [FF]

4

U32

0

232-1

5000

5000

ü

R/Z

-

-

DRIVECOM \ Acceleration

Acc delta speed [FF]

21

U32

0

232-1

100

100

ü

R/W

-

-

Acc delta time [s]

22

U16

0

65535

1

1

ü

R/W

-

-

DRIVECOM \ Deceleration

Dec delta speed [FF]

29

U32

0

232-1

100

100

ü

R/W

-

-

Dec delta time [s]

30

U16

0

65535

1

1

ü

R/W

-

-

DRIVECOM \ Quick stop

QStp delta speed [FF]

37

U32

0

232-1

1000

1000

ü

R/W

-

-

QStp delta time [s]

38

U16

0

65535

1

1

ü

R/W

-

-

Quick stop

Quick stop

No Quick stop

343

U16

0

1

No Quick

stop

No Quick

stop

-

R/W

0

1

-

-

DRIVECOM \ Face value fact

Face value num

54

I16

1

32767

1

1

ü

R/Z

-

R

Face value den

53

I16

1

32767

1

1

ü

R/Z

-

R

DRIVECOM \ Dimension fact

Dim factor num

50

I32***

1

65535

1

1

ü

R/Z

-

R

Dim factor den

51

I32***

1

231-1

1

1

ü

R/Z

-

R

Dim factor text

52

Text

rpm

rpm

ü

R/Z

-

-

DRIVECOM

Speed base value [FF]

45

U32***

1

16383

1500

1500

ü

R/Z

-

R

Speed input perc [%]

46

I16

-32768

+32767

0

0

ü

R/W

-

R/W

Percent ref var [%]

116

I16

-32768

+32767

ü

R

-

R

Act percentage [%]

120

I16

-32768

+32767

ü

R

-

R

SERVICE

Password 2

* When the parameter is accessed by Opt2-A/PDC the format is U16
** When the parameter is accessed by Opt2-A/PDC the format is I16
*** When the parameter is accessed by Opt2-A/PDC the lower word of the parameter is considered

Advertising