Control of the speed reference – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 316

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

188

Control of the speed reference

In order to calculate the speed reference during the different functioning phases of the machine, a status logic

has been developed. The status sequence and the operativeness is described in the figure 6.17.3.

Status 1

(default)

Status 2

Status 3

Status 4

Status 5

Start

(drive

)

=

1

Start (drive) = 1

Start (drive) = 0

Start

(drive)

=

0

Start (drive) = 0

Speed match = 1

Speed match = 0

Spee

d

0

thr

=

1

Int acc time = 0

Int dec time = 0

Int offset acc time = Offset acc time

Int w offset = W offset

Int acc time = Spd match acc

Int dec time = 0

Int offset acc time = 0

Int w offset = 0

Int acc time = 0

Int dec time = Spd match dec

Int offset acc time = 0

Int w offset = 0

Int acc time = 0

Int dec time = 0

Int offset acc time = 0

Int w offset = W offset

Figure 6.17.3: Operative sequence of the functioning status

Status 1:

Default status, this system condition is given when the drive is in a Stop condition. The speed reference is zero.

Status 2:

The system reaches this status when the Start command is given.

When the line is stopped, the initial phase reference W offset is assigned with the ramp time Offset acc time.

When the line is started, the motor speed reference follows its profile with a value corresponding to:

W reference = ± Line speed x (Minimum diameter ÷ Roll diameter) ± (W gain % + W offset)

the sign of:

± Line speed x (Minumum diameter ÷ Roll diameter)

is positive if Wind/unwind = winder

is negative if Wind/unwind = unwinder

the sign of:

± (W gain % + W offset)

is usually positive, it could be changed only if during the acceleration or deceleration phases a torque inver-

sion is required.

The polarity of W reference will be further inverted if Winder side = 1

(winding/unwinding down).

If during a Status 1functioning period the system receives a Stop command (Start drive = 0), the Status 5 is

forced.

Advertising