——— FUNCTION DESCRIPTION ———

6

35

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Enable spd=0 I

Enabled (1)

Disabled (0)

123

0

1

Disabled

Disabled

-

Enable spd=0 R

Enabled (1)

Disabled (0)

124

0

1

Disabled

Disabled

-

Enable spd=0 P

Enabled (1)

Disabled (0)

125

0

1

Disabled

Disabled

-

Spd=0 P gain [%]

126

0.00

100.00

10.00

10.00

-

Ref 0 level [FF]

106

1

32767

10

10

-

Enable spd=0 I

Enabled

The I component of the speed regulator is set to 0 when the

reference value and the actual value = 0. The drive control is

then only proportional. The I component is enabled when a

reference value is entered to restart acceleration.

Disabled

Disable the function.

Enable spd=0 R

Only effective if Enable spd=0 P is enabled.

Enabled

The proportional gain, equal to Spd=0 P gain at zero speed,

is equal to Speed P when the speed reference becomes higher

than the value defined by Ref 0 level.

Disabled

The proportional gain, equal to Spd=0 P gain at zero

speed, is equal to Speed P when the speed reference or

the actual speed become higher than the value defined by

Ref 0 level.

Enable spd=0 P

Enabled

When both reference value and actual value = 0, the propor-

tional Spd=0 P gain component is active after the delay time

defined by Speed zero delay.

Disabled

The speed regulator also keeps its proportional gain component

when the drive is at a stop.

Spd=0 P gain

Proportional gain of the speed regulator, that is only active when both reference value

and actual value = 0, and if the Enable spd=0 P function has been enabled.

Ref 0 level

Switch threshold for speed zero logic. Defined in the dimension specified in the factor

function. Speeds below this threshold are defined as zero.

6.7.3 Speed up

SPEED REGULAT

Speed up

[445]

Speed up gain [%]

[446]

Speed up base [ms]

[447]

Speed up filter [ms]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed up gain [%]

445

0.00

100.00

0.00

0.00

-

Speed up base [ms]

446

0

16000

1000

1000

-

Speed up filter [ms]

447

0

1000

0

0

-