——— FUNCTION DESCRIPTION ———

6

23

6.5.2. Armature current limits (Current limits)

LIMITS

Current limits

[715]

T current lim type

[7]

T current lim [%]

[8]

T current lim + [%]

[9]

T current lim - [%]

[10]

In use Tcur lim+ [%]

[11]

In use Tcur lim- [%]

[13]

Current lim red [%]

[342]

Torque reduct

The current effects the input of the current regulator and only take into account the armature current.

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

T current lim type

T lim +/- (0)

T lim mot gen (1)

715

0

1

0

0

-

T current lim [%]

7

0

200

150

150

**

T current lim + [%]

8

0

200

150

150

**

T current lim - [%]

9

0

200

150

150

**

Curr limit state

Curr. limit not reached (0)

Curr. limit reached (1)

349

0

1

Digital output 5 ***

In use Tcur lim+ [%]

10

0

200

-

In use Tcur lim- [%]

11

0

200

-

Current lim red [%]

13

0

200

100

100

-

Torque reduct

Not active (0)

Active (1)

342

0

1

Not active (0) Not active (0)

*

* This function can be assigned to one of the programmable digital inputs.

** This parameter can be assigned to a programmable analog input.

*** This function can be assigned to one of the programmable digital outputs.

T curr lim type

This parameters determines the behaviour of the drive in current limit condition.

T lim +/-

The active positive torque limit is T current lim and the active

negative torque limit is T current lim -.

T lim mot/gen

With this selection 3 conditions are possible:

1 - If the motor speed > +1% of Motor max speed the

active positive torque limit is T current lim+ and the ac-

tive negative torque limit is T current lim-.

2 - If the motor speed < -1% of Motor max speed the

active positive torque limit is T current lim- and the ac-

tive negative torque limit is T current lim+.

3 - If -1% of Motor max speed < motor speed < +1%

of Motor max speed the active positive torque limit is

T current lim+ and the active negative torque limit is T

current lim+.