44

6.10 REG pARAMETERS

REG PARAMETERS

Percent values

Speed regulator

[87]

Speed P [%]

[88]

Speed I [%]

[459]

Speed P bypass [%]

[460]

Speed I bypass [%]

Flux regulator

[91]

Flux P [%]

[92]

Flux I [%]

Voltage reg

[493]

Voltage P [%]

[494]

Voltage I [%]

Base values

Speed regulator

[93]

Speed P base [A/rpm]

[94]

Speed I base [A/rpm·ms]

Flux regulator

[97]

Flux P base

[98]

Flux I base

Voltage reg

[495]

Voltage P base [f%/V]

[496]

Voltage I base [f%/V·ms]

In use values

[99]

Speed P in use [%]

[100]

Speed I in use [%]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed P [%]

87

0.00

100.00

10.00

10.00

-

Speed I [%]

88

0.00

100.00

1.00

1.00

-

Speed P bypass [%]

459

0.00

100.00

10.00

10.00

-

Speed I bypass [%]

460

0.00

100.00

1.00

1.00

-

Flux P [%]

91

0.00

100.00

2.00

2.00

-

Flux I [%]

92

0.00

100.00

1.00

1.00

-

Voltage P [%]

493

0.00

100.00

30.00

30.00

-

Voltage I [%]

494

0.00

100.00

40.00

40.00

-

Speed P base [A/rpm]

93

000.1

S

0.3 x P93max

P93max

0.3 x P93max

P93max

-

Speed I base [A/rpm·ms]

94

0.001

S

0.3

P94max

0.3

P94max

-

Flux P base

97

1

32767

3277

3277

-

Flux I base

98

1

32767

3277

3277

-

Voltage P base [f%/V]

495

0.0100

S

S

S

-

Voltage I base [f%/V·ms]

496

0.01

S

S

S

-

Speed P in use [%]

99

0.00

100.00

S

S

-

Speed I in use [%]

100

0.00

100.00

S

S

-

Advertising