GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

14

Enable drive

When the converter is controlled via the keypad, it is activated via the Enable drive parameter.

A voltage is also required on terminal 12. The Start command is required for starting

the drive.

Enabled

Enable drive

Disable

Drive disabled

Start/Stop

Using the keypad as Start/Stop control, if Enter key is pushed, the motor run at the speed

set.

Ramp red (d)

Total reference value for the ramp in units specified by the factor function.

Ramp ref (rpm)

Total reference value for the ramp in rpm

Ramp ref (%)

Total reference value for the ramp as a percentage of the Speed base value.

Ramp output (d)

Ramp output in units specified by the factor function.

Ramp outp (rpm)

Ramp output in rpm

Ramp output (%)

Ramp output as a percentage of the Speed base value

Speed ref (d)

Total speed reference value in units specified by the factor function.

Speed ref (rpm)

Total speed reference value in rpm

Speed ref (%)

Total speed reference value as a percentage of the Speed base value

Actual spd (d)

Actual speed in units specified by the factor function.

Actual spd (rpm)

Actual speed in rpm (revolutions per minute).

Actual spd (%)

Actual speed as a percentage of the Speed base value

F act spd (d)

Filtered value of Actual speed in units specified by the factor function.

F act spd (rpm)

Filtered value of Actual speed in rpm..

Act spd filter

1

st

order low pass filter time constant on Actual speed.

Enc 1 speed (rpm)

Actual speed measured by the encoder 1. The parameter is accessible only if the

Speed fbk sel = encoder 2 and a digital encoder is used as encoder 1

(interfacing with the drive by means of the 6KKDV300DES card).

Enc. 2 speed (rpm)

Actual speed measured by the encoder 2. The parameter is accessible only if

Spees bfk sel = encoder 2

Mains voltage

Mains voltage in V

Mains frequency

AC input frequency in Hz

Output power

Output power value in Kw

Output voltage

Armature Voltage U

dA

in V

AV

Motor current

Armature current in % of Full load curr.

F T curr (%)

Filtered value of Torque current in percentage.

T curr filter

1

st

order low pass filter time constant on Torque current.

T current ref

Total current reference value as a percentage of the Full load current

Flux reference

Field current (reference) as a percentage of Motor nom flux.

Flux curr (%)

Actual field current value as percentage of Motor nom flux.

Flux curr (A)

Actual field current value in amps.

Digital I/O

Status of the digital input and output of the base converter and the card

6KCV300TBO.

Display:

I 1 2 3 4 5 6 7 8 E S F

Q 1 2 3 4 5 6 7 8

An I/O is displayed only if a voltage is present on the corresponding terminal. E.g.,

if the inputs 4 and 6 are displayed, that means that the digital inputs 4 and 6 on the