GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

136

If Enabled and the DGF card is not present, will be generated the error:

OPT2 failure code 100-98 or OPT2 failure code 100-96.

n

ote

When using the 6KCV300DGF card (Option 2), all parameters listed in the “Opt2-A/PDC”

column of Parameter List (section 10.1 and 10.2) can be accessed through the automatic

asynchronous communication. Parameters listed in the High Priority Parameter List (sec-

tion 10.4) can be accessed by means of the automatic synchronous communication. (See

6KCV300DGF manual for more details.)

If the software has detected the presence of the 6KCV300DGF the parameter set of the optional

card is accessible. In this case see the 6KCV300DGF user manual for detailed information.