Winder/unwinder control with dancer, Machine data, Input/output – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 289

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

161

Winder/Unwinder control with dancer

M

M

E

-10V

+10V

Feed-forward

Feed-back

5Kohm

+10V

-10V

E

R

(Internal ramp

master drive)

Line speed

reference

Forward

Reverse

DRIVE

DRIVE

Winder/unwinder

Dancer

Forward

Reverse

Nip-roll

Figure 6.16.3.10: Winder/Unwinder control with dancer

Machine data:

Max. line speed =400m/min
Rated speed of the motor winder/unwinder Vn = 3000rpm
Max. diameter of the winder/unwinder = 700mm
Min. diameter of the winder/unwinder = 100mm
Reduction ratio motor-coil = 0.5
One pitch dancer
Dancer stroke from the lower limit switch to the position of electric 0 = 160mm
The drive of the winder/unwinder must be sent the analog signals regarding line speed and the position of the

dancer (whose potentiometer will be supplied between the terminals -10V... +10V) and the digital commands

regarding the enabling of the PID control.
The regulator output will be sent to the speed reference 1.
Drive setting: (below are only the parameters regarding the PID function)

Input/output

Set Analog input 1 as input for the cursor of the dancer.
Analog input 1 / Select input 1= PID Feed-back

Set Analog input 2 as line speed input (feed- forward).

Advertising