GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 451

Advertising
background image

DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

57

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Reset flux / if

920

U16

0

1

0

0

ü

Z/C

-

Out vlt level

921

Float*

0.00

100.0

100.0

100.0

ü

R/W

IA, QA

R/W

Act spd filter [s]

923

Float

0.001

1.000

0.100

0.100

ü

R/W

-

-

Act spd filter [s]

923

Float

0.001

1.000

0.100

0.100

ü

R/W

-

-

F act spd (rpm)

924

I16

-32768

+32767

-

-

ü

R

QA

R

F act spd (d) [FF]

925

I16

-32768

+32767

-

-

ü

R

-

R

T curr filter [s]

926

Float

0.001

0.250

0.100

0.100

ü

R/W

-

-

F T curr (%)

928

I16

-500

+500

-

-

ü

R

QA

R

Inertia c filter [ms]

1012

U16

0

1000

0

0

ü

R/W

-

-

Torque const [N*m/A]

1013

Float

0.01

99.99

S

S

ü

R

-

-

Inertia [kg*m*m*]

1014

Float

0.001

999.999

S

S

ü

R/W

-

-

Friction [N*m]

1015

Float

0.000

99.999

S

S

ü

R/W

-

-

Aux spd fun sel

Speed up

Inertia-loss cp

1016

U16

0

1

Speed up

(0)

Speed up

(0)

ü

R/Z

0

1

-

-

Speed ratio

1017

I16

0

+32767

+10000

+10000

ü

R/W

IA

R/W

Speed draw out (d)

1018

I16

-32768

+32767

-

-

ü

R

QA

R/W

Speed draw out (%)

1019

Float

-200.0

+200.0

-

-

ü

R

-

-

Select enc 1

OFF

Speed ref 1

Speed ref 2

Ramp ref 1

Ramp ref 2

1020

U16

0

5

OFF

(0)

see 6.12.05

OFF

(0)

see 6.12.05

ü

R/Z

0

2

3

4

5

-

-

Select enc 2

OFF

Speed ref 1

Speed ref 2

Ramp ref 1

Ramp ref 2

1021

U16

0

5

OFF

(0)

see 6.12.05

OFF

(0)

see 6.12.05

ü

R/Z

0

2

3

4

5

-

-

Start

1027

U16

0

65535

-

-

ü

C

-

-

Take val

1028

U16

0

65535

-

-

ü

Z/C

-

-

Fwd-Rev spd tune

Fwd direction

Rev direction

1029

U16

1

2

Fwd

Direction

(1)

Fwd

Direction

(1)

ü

R/Z

1

2

-

-

Inertia Nw [kg*m*m*]

1030

Float

0.001

999.999

-

-

ü

R

-

-

Friction Nw [N*m]

1031

Float

0.000

99.99

-

-

ü

R

-

-

Speed P Nw [%]

1032

Float

0.00

100.00

-

-

ü

R

-

-

Speed I Nw [%]

1033

Float

0.00

100.00

-

-

ü

R

-

-

Input 1 compare

1042

I16

-10000

+10000

0

0

ü

R/W

-

-

Input 1 cp error

1043

U16

0

10000

0

0

ü

R/W

-

-

Input 1 cp delay

1044

U16

0

65000

0

0

ü

R/W

-

-

Input 1 cp match

Input 1 not thr.val.

Input 1=thr.val

1045

U16

0

1

-

-

-

R

0

1

QD

L

H

R

PID acc time

1046

Float

0.0

900.0

0.0

0.0

ü

R/W

-

-

PID dec time

1047

Float

0.0

900.0

0.0

0.0

ü

R/W

-

-

Test T curr lim [%]

1048

U16

0

S

20

20

ü

R/Z

-

-

Output power [kW]

1052

Float

0.01

9999.99

-

-

ü

R

-

-

Maximum diameter [m]

1153

Float

0.000

32.000

1.000

1.000

ü

R/Z

-

-

Advertising