DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

185

6.17.2.2 Taper function

OPTIONS

Torque winder

Torque calculat

Taper function

[1176]

Taper enable

[1177]

Init diameter [m]

[1178]

Final diameter [m]

[1180]

Tension ref [%]

[1179]

Tension red [%]

[1194]

Act tension ref [%]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Taper enable

Enabled (1) / Disabled (0)

1176

0

1

Disabled (0)

Disabled (0)

*

Init diameter [m]

1177

0.000

32.000

0.1

0.1

Final diameter [m]

1178

0.000

32.000

1

1

Tension ref [%]

1180

0.00

199.99

0

0

**

Tension red [%]

1179

0.00

199.99

0

0

**

Act tension ref [%]

1194

0.00

200.00

0

0

***

*

This parameter can be set on a programmable digital input.

** This parameter can be set on a programmable analog input.
*** This parameter can be set on a programmable analog output.

Tension ref

Min

diameter

Max

diameter

Init

diameter

Final

diameter

Tension ref x 1 -

Tension red

100

Roll diameter

Act tension ref

Figure 6.17.2: Relation among the Taper function parameters

Taper enable

Enabling of Taper function.

Init diameter

Diameter for the starting of the taper tension reduction in meters.

Final diameter

Diameter for the ending of the taper tension reduction in meters.

Tension ref

Tension reference in %.

Tension red

Taper tension reduction as a percentage of Tension ref.

Act tension ref

Monitor for the active tension reference as a percentage of Tension ref.