12 i/o config, Figure 6.12.1: arrangement of the programmable i/o, Tbo "a” integrated – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 192: Tbo "b

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

64

The message Wrong password appears if an incorrect password is entered.
If the drive shows the message EEPROM the password is deactivated. This takes place the first time the drive

is switched on and after a possible change of the operating system.

On delivery the Service menu of the drive is protected by Password 2. No Pword 1 has been entered. The user

has free access to all parameters.
Password 2
cannot be deactivated.

n

ote

:

In case personal password has been forgotten, it is possible to deactivate it through the setting

of the universal password.

The code of this password is: 51034

The setting mode of this one remains unchanged compared to the personal password.

6.12 I/O CONFIG

ENC 1

ENC 2

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 2

23 24 25 26 27 28 29 30 31 32 33 34 37 38 39 40 41 42

21 22

Digital

input

2

Digital

input

1

Digital

input

3

Digital

input

4

Com

digital

inputs

A

Analog

output

1

Analog

output

2

Com

analog

output

1

Com

digital

outputs

A

Digital

output

1

Digital

output

2

Digital

output

3

Digital

output

4

Supply

dig

outputs

A

TBO "A” integrated

Com

analog

output

2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

XB

1

2

19

20

TBO

Analog

output

3

Com

analog

output

3

Analog

output

4

Com

analog

output

4

Com

digital

outputs

B

Digital

output

5

Digital

output

6

Digital

output

7

Digital

output

8

Supply

dig

outputs

B

Digital

input

5

Digital

input

6

Digital

input

7

Digital

input

8

Com

digital

inputs

B

TBO "B"

Analog

input

1

Analog

input

2

Analog

input

3

Figure 6.12.1: Arrangement of the programmable I/O

Apart from the terminals which have fixed functions (e.g. for Enables), the converters of the DV-300 series

provide the possibility of assigning freely programmable inputs/outputs to particular functions. This can either

be carried out via the keypad, the serial interface or any bus connection present.
The freely programmable inputs/outputs are factory set for assignment to the most frequently required functions.

However, these can be modified by the user accordingly to meet the requirements of the applicationn at hand.
The device inputs/outputs are subdivided as follows:

- converter with integrated TBO “A”:

3 Analog inputs (1...3), designed as differential inputs

2 Analog outputs (1 and 2) with common reference point

4 Digital outputs (1...4) with common reference point and common voltage supply

4 Digital inputs (1...4) with common reference point.