GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 402

Advertising
background image

GEI-100332Ga

——— PARAMETER LISTS ———

10

8

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Dig input term 3

567

U16

0

1

-

-

-

R

-

R

Dig input term 4

568

U16

0

1

-

-

-

R

-

R

Dig input term 5

569

U16

0

1

-

-

-

R

-

R

Dig input term 6

570

U16

0

1

-

-

-

R

-

R

Dig input term 7

571

U16

0

1

-

-

-

R

-

R

Dig input term 8

572

U16

0

1

-

-

-

R

-

R

Dig input term 9

573

U16

0

1

-

-

-

R

-

R

Dig input term 10

574

U16

0

1

-

-

-

R

-

R

Dig input term 11

575

U16

0

1

-

-

-

R

-

R

Dig input term 12

576

U16

0

1

-

-

-

R

-

R

Dig input term 15

579

U16

0

1

-

-

-

R

-

R

Dig input term 16

580

U16

0

1

-

-

-

R

-

R

Dig output term

581

U16

0

65535

-

-

R

-

R

Virtual dig inp

582

U16

0

65535

-

-

ü

R

-

-

Virtual dig out

583

U16

0

65535

-

-

ü

R

-

-

INPUT VARIABLES \ Ramp ref \ Ramp ref 1

Ramp ref 1 [FF]

44

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Ramp ref 1 (%)

47

Float

-200.0

+200.0

0.0

0.0

ü

R/W

-

-

INPUT VARIABLES \ Ramp ref \ Ramp ref 2

Ramp ref 2 [FF]

48

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Ramp ref 2 (%)

49

Float

-200.0

+200.0

0.0

0.0

ü

R/W

-

-

INPUT VARIABLES \ Speed ref \ Speed ref 1

Speed ref 1 [FF]

42

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Speed ref 1 (%)

378

Float

-200.0

+200.0

0

0

ü

R/W

-

-

INPUT VARIABLES \ Speed ref \ Speed ref 2

Speed ref 2 [FF]

43

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Speed Ref 2 (%)

379

Float

-200.0

+200.0

0

0

ü

R/W

-

-

INPUT VARIABLES \ T current ref

T current ref 1 [%]

39

I16

-200

+200

see 6.4.3

0

0

ü

R/W

IA, QA

R/W

T current ref 2 [%]

40

I16

-200

+200

0.00

0.00

ü

R/W

IA, QA

-

LIMITS \ Speed limits \ Speed amount

Speed min amount [FF]

1

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max amount [FF]

2

U32

0

232-1

5000

5000

ü

R/Z

-

-

LIMITS \ Speed limits \ Speed min/max

Speed min pos [FF]

5

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max pos [FF]

3

U32

0

232-1

5000

5000

ü

R/Z

-

-

Speed min neg [FF]

6

U32

0

232-1

0

0

ü

R/Z

-

-

Speed max neg [FF]

4

U32

0

232-1

5000

5000

ü

R/Z

-

-

Speed limited

Speed not limited

Speed limited

372

U16

0

1

-

R

0

1

QD

L

H

R

0

1

LIMITS \ Current limits

T current lim type

T lim +/-

T lim mot gen

715

U16

0

1

0

0

ü

R/Z

0

1

-

-

T current lim [%]

7

U16

0

200

150

150

ü

R/W

IA

R/W

T current lim + [%]

8

U16

0

200

150

150

ü

R/W

IA

R/W

T current lim - [%]

9

U16

0

200

150

150

ü

R/W

IA

R/W

Curr limit state

Curr. limit not reached

Curr. limit reached

349

U16

0

1

-

R

0

1

QD

L

H

R

0

1

Advertising