GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 210

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

82

The adaptive speed regulator function enables different gains of the speed regulator depending on the speed or another

variable (Adaptive Reference). This allows optimum adaptation of the speed regulator to the applicaion at hand.

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Enable spd adap

Enabled (1)

Disabled (0)

181

0

1

Disabled

Disabled

-

Select adap type

Speed (0)

Adap reference (1)

Parameter (2)

182

0

2

Speed

Speed

-

Adap reference [FF]

183

-32768

+32767

1000

1000

*

Adap selector

1464

0

3

0

0

-

Adap speed 1 [%]

184

0.0

200.0

20.3

20.3

-

Adap speed 2 [%]

185

0.0

200.0

40.7

40.7

-

Adap joint 1 [%]

186

0.0

200.0

6.1

6.1

-

Adap joint 2 [%]

187

0.0

200.0

6.1

6.1

-

Adap P gain 1 [%]

188

0.00

100.00

10.00

10.00

-

Adap I gain 1 [%]

189

0.00

100.00

1.00

1.00

-

Adap P gain 2 [%]

190

0.00

100.00

10.00

10.00

-

Adap I gain 2 [%]

191

0.00

100.00

1.00

1.00

-

Adap P gain 3 [%]

192

0.00

100.00

10.00

10.00

-

Adap I gain 3 [%]

193

0.00

100.00

1.00

1.00

-

Adap P gain 4 [%]

1462

0.00

100.00

10.00

10.00

-

Adap I gain 4 [%]

1463

0.00

100.00

1.00

1.00

-

* This function can be assigned to one of the programmable analog inputs.

Enable spd adap

Enabled

Adaptive speed regulation enabled.

Disabled

Adaptive speed regulation is not enabled. The regulator operates

with the parameters set in the REG PARAMETERS menu.

Select adap type

Speed

The regulator parameters are modified according to the speed.

Adap reference

The regulator parameters are modified according to the Adap

reference parameter.

Parameter

It allows to change the gains via parameter or via dual digital input.

Only in these operating conditions are 4 sets of PI gains available.

Adap reference

The variable according to which the speed regulator parameters are to be modified (only

with Select adap type = Adap reference).

Adap selector

The Adap selector parameter selects a pair of parameters: Adap P gain and Adap I

gain from 1 to 4, if Sel adap type is set to Parameter. If the Adap selector parameter is

programmed on digital inputs Adapt Sel 1 or Adapt Sel 2, it only indicates which pair

of gains has been selected.

Adap speed 1

Parameter set 1 is valid below this point, and parameter set 2 above it. The transition

behaviour between the values is defined by the Adap joint 1 parameter. The definition

is a percentage of the Speed base value and the maximum value of Adap reference.

Adap speed 2

Parameter set 2 is valid below this point, and parameter set 3 above it. The transition

behaviour between the values is defined by Adap joint 2. The definition is a percentage

of the Speed base value and the maximum value of Adap reference.

Adap joint 1

Defines a range around Adap speed 1 in which there is a linear change in gain from

parameter set 1 to parameter set 2 in order to prevent jumps in the behavior of the regu-

lator. It is defined as a percentage of Speed base value.

Advertising