GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 141

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

13

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Enable drive

Enabled (1)

Disabled (0)

314

0

1

Disabled

Disabled

Terminal 12

+15 ... 30 V

0 V

Start/Stop

Start (1)

Stop (0)

315

0

1

Stop (0)

Stop (0)

Terminal 13

+15 ... 30 V

0 V

Ramp ref (d) [FF]

109

-32768

+32767

-

-

-

Ramp ref (rpm)

110

-32768

+32767

-

-

*

Ramp ref (%)

111

-200.0

+200.0

-

-

-

Ramp output (d) [FF]

112

-32768

+32767

-

-

-

Ramp outp (rpm)

113

-32768

+32767

-

-

*

Ramp output (%)

114

-200.0

+200.0

-

-

-

Speed ref (d) [FF]

115

-32768

+32767

-

-

-

Speed ref (rpm)

118

-32768

+32767

-

-

*

Speed ref (%)

117

-200.0

+200.0

-

-

-

Actual spd (d) [FF]

119

-32768

+32767

-

-

-

Actual spd (rpm)

122

-8192

+8192

-

-

An Output 1 *

Actual spd (%)

121

-200.0

+200.0

-

-

-

F act spd (rpm)

924

-32768

+32767

-

-

*

Act spd filter [s]

923

0.001

1.000

0.100

0.100

-

Enc 1 speed (rpm)

427

-8192

+8192

-

-

-

Enc 2 speed (rpm)

420

-8192

+8192

-

-

-

Mains voltage [V]

466

0

999

-

-

*

Mains frequency [Hz]

588

0.0

70.0

-

-

-

Output power [Kw]

1052

0.01

9999.99

-

-

-

Output voltage [V]

233

0

999

-

-

*

Motor current [%]

199

-250

250

-

-

*

F T curr (%)

928

-500

+500

-

-

*

T curr filter [s]

926

0.001

0.250

0.100

0.100

-

T current ref [%]

41

-200

+200

-

-

*

Flux reference [%]

500

0.0

100.0

-

-

*

Flux current [%]

234

0.0

100.0

-

-

*

Flux current (A)

351

0.1

99.9

S

S

-

Digital I/Q

-

-

-

Dig input term 1

565

0

1

-

-

-

Dig input term 2

566

0

1

-

-

-

Dig input term 3

567

0

1

-

-

-

Dig input term 4

568

0

1

-

-

-

Dig input term 5

569

0

1

-

-

-

Dig input term 6

570

0

1

-

-

-

Dig input term 7

571

0

1

-

-

-

Dig input term 8

572

0

1

-

-

-

Dig input term 9

573

0

1

-

-

-

Dig input term 10

574

0

1

-

-

-

Dig input term 11

575

0

1

-

-

-

Dig input term 12

576

0

1

-

-

-

Dig input term 15

579

0

1

-

-

-

Dig input term 16

580

0

1

-

-

-

Dig output term

581

0

65535

-

-

-

Virtual dig inp

582

0

65535

-

-

-

Virtual dig out

583

0

65535

-

-

-

* This function can be assigned to a programmable analog output.