GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

56

Dim factor num

4

Dim factor den

3

Dim factor text

F/min (bottles per minute)

Example of the face value factor

Normally the reference value has a resolution of 1 rpm. In order to exploit the available resolution, the face

value factor is used.
The motor speed range required is, for example, 0...1500 rpm. A more accurate resolution (i.e. 1/4 revolution)

can be obtained by setting hte face value factor to 1/4.
The value 4 000 is entered, for example, in order to select 1000 rpm This is then multiplied with the face value

factor to give the value 1000 rpm.

Face value num

1

Face value den

4

6.11.7. programmable alarms

CONFIGURATION

Prog alarms

Failure supply

[194]

Latch

[195]

Ok relay open

Undervoltage

[481]

Undervolt thr [V]

[357]

Latch

[358]

Ok relay open

[470]

Hold off time [ms]

[359]

Restart time [ms]

Overvoltage

[203]

Activity

[361]

Latch

[362]

Ok relay open

[482]

Hold off time [ms]

[483]

Restart time [ms]

Overspeed

[1426]

Overspeed thr [rpm]

[1422]

Activity

[1421]

Latch

[1423]

Ok relay open

[1424]

Hold off time [ms]

[1425]

Restart time [ms]

Heatsink

[368]

Activity

[370]

Ok relay open

Overtemp motor

[365]

Activity