Figure 6.14.4.2: multi ramp selection via signals – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 225

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

97

F

Multi Ramp Function

Speed

Reference Ramp

Single ramp

Ramp out

Ramp inp

15

1

1

12

13

14

19

18

+24V

0V

24

Digital

input

1

Digital

input

2

Digital

input

3

Digital

input

4

CO

M

D

I/O

2

0

2

1

6KCV300TBO

Enab multi rmp

Ramp

sel

0

Bi

t

0

Not

Selected

Ramp

sel

1

Bi

t

1

Not

Selected

Figure 6.14.4.1: Multi ramp selection via terminals

F

F

Linear

Ramp

shape

selection

S-shape

Multi Ramp Function

Speed

t

Reference Ramp

Single ramp

Enab multi rmp

Ramp shape

S acc t const 0

300 ms

S acc t const 1

300 ms

S acc t const 2

300 ms

S acc t const 3

300 ms

S dec t const 3

300 ms

S dec t const 0

300 ms

S dec t const 1

300 ms

S dec t const 2

300 ms

Acc delta speed 1

100 rpm

Dec delta speed 1

100 rpm

Acc delta speed 2

100 rpm

Dec delta speed 2

100 rpm

Acc delta speed0

100 rpm

Acc delta speed 3

100 rpm

Dec delta speed0

100 rpm

Dec delta speed 3

100 rpm

Acc delta time 0

1 s

Acc delta time 1

1 s

Acc delta time 2

1 s

Acc delta time 3

1 s

Dec delta time 0

1 s

Dec delta time 1

1 s

Dec delta time 2

1 s

Dec delta time 3

1 s

Figure 6.14.4.2: Multi ramp selection via signals

Advertising