5 speed draw function, Figure 6.14.5.1: speed draw block diagram – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 226

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

98

6.14.5 Speed Draw function

FUNCTIONS

Speed draw

[1017]

Speed ratio

[1018]

Speed draw out (d)

[1019]

Speed draw out (%)

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed ratio

1017

0

+32767

+10000

+10000

Speed draw out (d)

1018

-32768

+32767

-

-

Speed draw out (%)

1019

-200.0

+200.0

-

-

To Max speed limits

Speed ratio

10000

Speed ratio

10000

Speed draw out

Enable ramp

T

From Ramp output

Speed ref 2

0 rpm

Speed ref 1

0 rpm

Figure 6.14.5.1: Speed draw block diagram

This function allows a configurable Speed ratio to be applied to the main reference Speed ref 1.
The Speed ratio range can be set between 0 and 32767 if written in digital form. It can be set from 0 to 20000

(0 to +10V) if assigned via an analog input.
This function is useful in a multidrive system where between the motors is required (see example in figure

6.14.5.2).
The speed resulting value can be read through the Spd draw out parameter via an analog output.

Speed ratio

This parameter determines the speed ratio value.This setting can be done in digital form,

via LAN or through an analog input.

Spd draw out (d)

Speed value in the unit specified by the factor function.

Spd draw out (%)

Speed value as a percentage of Speed base value.