Figure 4.8.4: encoder and tachometer connections, Xe2 sinus encoder, Digital encoder – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 65

Advertising
background image

DV-300 Adjustable Speed Drives

——— WIRING PROCEDURES ———

4

21

A+

A- B+

B-

1

5

6

9

8

7

0V

5V

XE1

A+

A- B+

B-

1

5

6

2

8

7

0V

24V

XE2

Sinus encoder

-

+

Digital encoder

T

Analog tacho

S4-1...8

Voltage setting by

Figure 4.8.4: Encoder and Tachometer Connections

Analog outputs

1

2

21

22

23

24

Digital outputs

1

2

3

4

25

26

27

28

29

30

Supply

Digital inputs

37

31

32

33

34

1

2

3

4

19

18

0

V

24

+

24

V

0 V

+ 24 V

R-TPD3-GE

Figure 4.8.5: Programmable Inputs/outputs (option 6KCV300TBO) with relay and contacts

n

ote

!

To improve the noise immunity it is advisable to connect the common of the outputs (termi-

nals 22/24, 25/37 of 6KCV300TBO) with the ground (terminals 10 or 20 of the regulation

board). It is not possible, the above mentioned common have to be grouded by means of a

0,1 µF/250V capacitor.