——— FUNCTION DESCRIPTION ———

6

200

DIGITAL INPUT 3
Winder side

Selection of the winding/unwinding side: in case the selection is carried out via a digital

input: 0 =UP, 1 = Down

DIGITAL INPUT 4
Diam reset

Diameter reset. When this parameter is enabled, the diameter gets the starting value

selected with Diam preset sel.

If 2-4 different values of the starting diameter have been set, the selection has to be carried

out via some programmed digital inputs such as: Diam preset sel 0- Diam preset sel 0

If the value of the starting diameter is set via an analog input, set Diam preset sel = 3.

In case of a winder control, it is necessary to give a reset command every time a coil

change is performed by setting the minimum diameter value (winder empty diam.)

In case of an unwinder control, it is necessary to give a reset command every time a

coil change is performed by setting the maximum diameter value(winder maximum

diam.).

Enable the parameter Diam reset for a time longer than 20ms.

Reset the digital input status before the start

DIGITAL INPUT 5
Diam preset sel 0

DIGITAL INPUT 6
Diam preset sel 1

In case of a system with a winder or unwinder control, it is possible to set in Diam preset

0 the value of the starting diameter; for the winder control a minimum diameter, for the

unwinder control a maximum diameter. Set Diam preset sel =0 (do not set any digital

input as diam preset sel 0-diam preset 1). By starting the command of Diam reset the

value of diam preset 0 is entered in Roll diameter.

OPTION Menu

————> Torque winder

Torque winder En ; set Enable to enable the center wind function.

If the system requires it, it is possible to set this function (enable/disable)also via a

digital input.

Setting of the parameters in the DIAMETER CALCULATION menu

PARAMETERS

OPTION Menu

————> Torque winder

————> Diam calculation

Wind/unwind

Winder/unwinder selection. Selection to be carried out only if the digital inputs are not set.

Minimum diameter Minimum diameter value in [mm]. Set 100mm
Maximum diameter Maximum diameter value in [m]. Set 0.7m
Line spd source

Number of the sampling parameter of the line speed. In order to get the real number to

be set it is necessary to add +2000H (8192 decimal) to the parameter number.