Acc delta time 1

It defines together with Acc delta speed 1 the acceleration ramp 1. Defined in seconds.

S acc t const 1

Defines the acceleration curve for S-shape ramp 1. Defined in ms.

Dec delta speed1

It defines together with Dec delta time 1 the deceleration ramp 1. Defined by the units

specified in the factor function.

Dec delta time 1

It defines together with Dec delta speed 1 the deceleration ramp 1. Defined in seconds.

S dec t const 1

Defines the deceleration curve for S-shape ramp 1. Defined in ms.

Acc delta speed2

It defines together with Acc delta time 2 the acceleration ramp 2. Defined by the units

specified in the factor function.

Acc delta time 2

It defines together with Acc delta speed 2 the acceleration ramp 2. Defined in seconds.

S acc t const 2

Defines the acceleration curve for S-shape ramp 2. Defined in ms.

Dec delta speed2

It defines together with Dec delta time 2 the deceleration ramp 2. Defined by the units

specified in the factor function.

Dec delta time 2

It defines together with Dec delta speed 2 the deceleration ramp 2. Defined in seconds.

S dec t const 2

Defines the deceleration curve for S-shape ramp 2. Defined in ms.

Acc delta speed3

It defines together with Acc delta time 3 the acceleration ramp 3. Defined by the units

specified in the factor function.

Acc delta time 3

It defines together with Acc delta speed 3 the acceleration ramp 3. Defined in seconds.

S acc t const 3

Defines the acceleration curve for S-shape ramp 3. Defined in ms.

Dec delta speed3

It defines together with Dec delta time 3 the deceleration ramp 3. Defined by the units

specified in the factor function.

Dec delta time 3

It defines together with Dec delta speed 3 the deceleration ramp 3. Defined in seconds.

S dec t const 3

Defines the deceleration curve for S-shape ramp 3. Defined in ms.

Ramp sel 0

Ramp selection with the significance 2

0

(Bit 0). Parameter can only be used in conjunc-

tion with Ramp sel 1.

High

Significance 2

0

selected

Low

Significance 2

0

not selected

Ramp sel 1

Ramp selection with the significance 2

1

(Bit 1). Parameter can only be used in conjunc-

tion with Ramp sel 0.

High

Significance 2

1

selected

Low

Significance 2

1

not selected

See in the following table and graph the interaction between the selection and the ramp

Ramp

sel 0

Ramp

sel 1

Ramp 0

Low

Low

Ramp 1

High

Low

Ramp 2

Low

High

Ramp 3

High

High

GD6242g

Table 6.14.4.1: Ramp selection

In order to activate the Multiramp function, it must be enabled with the Enab multi rmp parameter.
The ramp required is selected via the Ramp sel 0 and Ramp sel 1 signals. When the selection is made via the

terminal strip, it is possible to select only one digital input. This configuration enables only the ramp time selected.

Another ramp can be selected at any time. If this happens during an acceleration or deceleration phase, the refer-

ence value will then follow the new ramp. The ramp parameter are defined via the keypad or serial line.