2 encoder / tachometer – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 40

Advertising
background image

GEI-100332Ga

——— DESCRIPTION, COMPONENT IDENTIFICATION AND SPECIFICATIONS ———

2

20

2.7.2 Encoder / Tachometer

The encoders and the tachometers give the speed feedback to the regulation. They have to be mounted on the

motor shaft with joints without gaps. The best regulation results are possible by using incremental sinusoidal

encoders; it is also possible to use digital incremental encoders or tachogenerators, see section, “Accuracy”.

Features:
Sinusoidal encoder

max frequency

150 kHz

number of pulses per revolution

min

600

max

9999

channel

two-channel

supply

+ 5V (internal supply)

load capacity

> 8.3 mA pp each channel

Digital encoder

max frequency

150 kHz

number of pulses per revolution

min

600

max

9999

channels

two-channel, with complementary outputs

supply

+ 5V / 15 ... 24V (external supply)

+ 24V (internal supply)

load capacity

> 4.5 mA / 6.8 ... 10.9 mA each channel

Analog tachometer

for 6KDV3...Q2...

DC tacho (recommended), rectified AC tacho

for 6KDV3...Q4...

DC tacho only

max voltage at max speed

22.7 / 45.4 / 90.7 / 181.6 / 302.9 V, depending on the

dip switch S4 setting

current

8 mA, full scale

Advertising