——— FUNCTION DESCRIPTION ———

6

84

6.13.3 Speed control

ADD SPEED FUNCT

Speed control

[101]

Spd threshold + [FF]

[102]

Spd threshold - [FF]

[103]

Threshold delay [ms]

[104]

Set error [FF]

[105]

Set delay [ms]

Two speed control messages are provided:

-

when a particular, adjustable speed is not exceeded.

-

when the speed corresponds to the set rference value

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Spd threshold + [FF]

101

1

32767

1000

1000

-

Spd threshold - [FF]

102

1

32767

1000

1000

-

Threshold delay [ms]

103

0

65535

100

100

-

Spd threshold

Speed exceeded (0)

Speed not exceeded (1)

393

0

1

Digital output 3 *

Set error [FF]

104

1

32767

100

100

-

Set delay [ms]

105

1

65535

100

100

-

Set speed

Speed not ref. val. (0)

Speed = ref. val. (1)

394

0

1

-

* This function can be assigned to a programmable digital output.

Spd threshold +

Switch point for the “Speed not exceeded” for clockwise rotation of the drive in the

units defined by the Factor funtion.

Spd threshold -

Switch point for the “Speed not exceeded” for counter-clockwise rotation of the drive

in the units defined by the Factor funtion.

Threshold delay

Setting of a delay time in milliseconds which is active when the speed is lowered within

the limits of the set threshold.

Spd threshold

Message “Set speed not exceeded” (via a programmable digital input)

High Speed not exceeded

Low Speed exceeded

Set error

Defines a tolerance band around the speed reference in the units specified by the Factor function.

Set delay

Setting of a delay time in milliseconds which is active when the speed is lowered within

the limits of the set threshold.

Set speed

Message “The speed corresponds to the reference value” (via a programmable digital output)

High Speed corresponds to the reference value

Low Speed does not corresponds to the reference value

The message “The speed corresponds to the reference value” refers to the total reference value in front of the

Speed ref speed regulator and to the Ramp Ref ramp reference when the ramp is selected.
When the references are lower than ± 1 %, the signal is always low!