DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

15

6KCV300TBO card are to High level.

E= Enable drive (terminal 12)

S= Start (terminal 13)

F= Fast stop (terminal 14)

When a serial line or a Bus is used, the status of the digital I/O can be read by means

of the Dig input term and Dig output term parameters.

Dig input term

Status of the digital inputs on the device and 6KCV300TBO option card to be read by

serial line or field bus. The information is contained in a word, where each bit is 1 if

voltage is present on the corresponding input terminal.

Bit n.

output

Bit n.

Input

0

TBO “A”, Term. 31

(Digital input 1)

8

DV-300, Term. 12

(Enable drive)

1

TBO “A”, Term. 32

(Digital input 2)

9

DV-300, Term. 13

(Start)

2

TBO “A”, Term. 33

(Digital input 3)

10

DV-300, Term. 14

(Fast stop)

3

TBO “A”, Term. 34

(Digital input 4)

4

TBO “B”, Term. 11

(Digital input 5)

5

TBO “B”, Term. 12

(Digital input 6)

6

TBO “B”, Term. 13

(Digital input 7)

7

TBO “B”, Term. 14

(Digital input 8)

GD6035g

Dig input term 1*

Status of the digital input 1 (terminal 21, integrated TBO “A”)

Dig input term 2*

Status of the digital input 2 (terminal 22, integrated TBO “A”)

Dig input term 3*

Status of the digital input 3 (terminal 23, integrated TBO “A”)

Dig input term 4*

Status of the digital input 4 (terminal 24, integrated TBO “A”)

Dig input term 5*

Status of the digital input 5 (terminal 11, option 6KCV300TBO, TBO “B”)

Dig input term 6*

Status of the digital input 6 (terminal 12, option 6KCV300TBO, TBO “B”)

Dig input term 7*

Status of the digital input 7 (terminal 13, option 6KCV300TBO, TBO “B”)

Dig input term 8*

Status of the digital input 8 (terminal 14, option 6KCV300TBO, TBO “B”)

Dig input term 9*

Status of the digital input on terminal 12 (Enable drive)

Dig input term 10*

Status of the digital input on terminal 13 (Start)

Dig input term 11*

Status of the digital input on terminal 14 (Fast stop)

Dig input term 12*

Not used

Dig input term 13*

Not used

Dig input term 14*

Not used

Dig input term 15*

Not used

Dig input term 16*

Not used

Dig output term

Status of the digital outputs on the device and 6KCV300TBO option card to be read

by serial line or field bus. The information is contained in a word, where each bit is 1

if voltage is present on the corresponding terminal.

Advertising