GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 403

Advertising
background image

DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

9

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

In use Tcur lim+ [%]

10

U16

0

200

ü

R

-

R

In use Tcur lim- [%]

11

U16

0

200

ü

R

-

R

Current lim red [%]

13

U16

0

200

100

100

ü

R/W

-

R/W

Torque reduct

Not active

Active

342

U16

0

1

Not active

(0)

Not active

(0)

ü

R/W

0

1

ID

L

H

R/W

0

1

LIMITS \ Flux limits (Fld curr limits)

Flux current max [%]

(Max field curr [%])

467

U16

P468

100

100

100

ü

R/W

-

R/W

Flux current min [%]

(Min field curr [%])

468

U16

0

P467

5

5

ü

R/W

-

----

RAMP \ Acceleration

Acc delta speed [FF]

21

U32

0

232-1

100

100

ü

R/W

-

-

Acc delta time [s]

22

U16

0

65535

1

1

ü

R/W

-

-

RAMP \ Deceleration

Dec delta speed [FF]

29

U32

0

232-1

100

100

ü

R/W

-

-

Dec delta time [s]

30

U16

0

65535

1

1

ü

R/W

-

-

RAMP \ Quick stop

QStp delta speed [FF]

37

U32

0

232-1

1000

1000

ü

R/W

-

-

QStp delta time [s]

38

U16

0

65535

1

1

ü

R/W

-

-

RAMP

Ramp shape

Linear

S-Shaped

18

U16

0

1

Linear

(0)

Linear

(0)

ü

R/Z

0

1

-

-

S shape t const [ms]

19

Float

100

3000

300

300

ü

R/W

-

-

S acc t const [ms]

663

Float

100

3000

300

300

ü

R/W

-

-

S dec t const [ms]

664

Float

100

3000

300

300

ü

R/W

-

-

Ramp +/- delay [ms]

20

U16

0

65535

100

100

ü

R/W

-

-

Fwd-Rev

No direction

Fwd direction

Rev direction

No direction

673

U16

0

3

1

1

ü

R/W

0

1

2

3

ID

R/W

0

1

2

3

Forward sign

293

U16

0

1

0

0

-

R/W

ID

R/W

Reverse sign

294

U16

0

1

0

0

-

R/W

ID

R/W

Enable ramp

Enabled

Disabled

245

I16

0

1

Enabled

(1)

Enabled

(1)

ü

R/Z

1

0

-

-

Ramp out = 0

Active

Not active

344

U16

0

1

Not active

(1)

Not active

(1)

ü

R/W

0

1

ID

L

H

R/W

0

1

Ramp in = 0

Active

Not active

345

U16

0

1

Not active

(1)

Not active

(1)

ü

R/W

0

1

ID

L

H

R/W

Freeze ramp

Active

Not active

373

U16

0

1

Not active

(1)

Not active

(1)

ü

R/W

0

1

ID

H

L

R/W

1

0

Ramp +

Acc.CW + Dec. anti-CW

(Acc.clockwise + Dec. anti-

clockwise)

Other states

346

U16

0

1

-

-

-

R

1

0

QD

H

L

R

1

0

Advertising