DV-300 Adjustable Speed Drives

——— PARAMETER LISTS ———

10

15

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

CONFIGURATION \ Prog alarms \ Overtemp motor

Activity

Ignore

Warning

Disable drive

Quick stop

Normal stop

Curr lim stop

365

U16

Disable

dive

Disable

dive

ü

R/Z

0

1

2

3

4

5

-

-

Ok relay open

ON

OFF

367

I16

ON

ON

ü

R/W

1

0

-

-

CONFIGURATION \ Prog alarms \ External fault

Activity

Warning

Disable drive

Quick stop

Normal stop

Curr lim stop

354

U16

1

5

Disable

drive

Disable

drive

ü

R/Z

1

2

3

4

5

-

-

Latch

ON

OFF

355

U16

0

1

ON

ON

ü

R/Z

1

0

-

-

Ok relay open

ON

OFF

356

I16

0

1

ON

ON

ü

R/W

1

0

-

-

Hold off time [ms]

502

U16

0

10000

0

0

ü

R/W

-

-

Restart time [ms]

501

U16

0

10000

0

0

ü

R/W

-

-

CONFIGURATION \ Prog alarms \ Brake fault

Activity

Ignore

Warning

Disable drive

Quick stop

Normal stop

Curr lim stop

1296

U16

0

5

Disable

drive

Disable

drive

ü

R/Z

0

1

2

3

4

5

-

-

Ok relay open

ON

OFF

1297

I16

0

1

ON

ON

ü

R/W

0

1

-

-

CONFIGURATION \ Prog alarms \ Motor I2t ovrld

Activity

Ignore

Warning

Disable drive

1419

U16

0

2

Disable

drive

Disable

drive

ü

R/Z

0

1

2

-

-

Latch

ON

OFF

1442

U16

0

1

ON

ON

ü

R/Z

0

1

-

-

Ok relay open

ON

OFF

1420

I16

0

1

ON

ON

ü

R/W

0

1

-

-

CONFIGURATION \ Prog alarms \ Drive I2t ovrld

Ok relay open

ON

OFF

1441

I16

0

1

ON

ON

ü

R/W

0

1

-

-

CONFIGURATION \ Prog alarms \ Overcurrent

Overcurrent thr [%]

584

U16

0

200

160

160

ü

R/W

-

-

Activity

Ignore

Warning

Disable drive

212

U16

0

2

Ignore

Ignore

ü

R/Z

0

1

2

-

-