Provisions, Drive used as a winder – winding side = up – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 336

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

208

provisions

In order to make the commissioning procedure easier and uniform, the system contains a clause referring to the

speed and torque directions to be respected:

As a general rule the winder speed and the torque direction are considered positive with a upper winding side.

All the possible system configurations stated in the examples below refer to this clause.

n

ote

!

The polarity of the line speed reference is not important, because the system states the output

reference polarity only according to the parameters Wind/unwind and Winder side.

1. Drive used as a winder – winding side = up

M

W[+]

DRIVE

R

Line speed

T[+]

M

Nip roll

Winder

Winder side = Up

Wind/unwind = Winder

Figure 6.17.13: Drive used as a winder – winding side = up

If the speed demand function is used, the system creates a positive speed reference; it is therefore necessary to

connect the motor so that, with this polarity, the coil winds the material starting from the upper side. The wind-

ing torque is positive.

Advertising