Input/output

Set Analog input 1 as input for the load cell signal.
Analog input 1 / Select input 1= PID Feed-back

Set Analog input 2 as line speed input (feed- forward).
Setting the feed-forward on analog input, seeing it is not directly inserted in the list of high-priority parameters,

it is necessary to pass through a supporting parameter PAD 0.....PAD 15.
Analog input 2 / Select input 2 = PAD 0

Set Analog input 3 as input for the tension set (PID offset 0).
Analog input 3 / Select input 3 / PID offset 0

Set Digital input 1 as enabling input of the PI block of the PID
Digital input 1 = Enable PI PID

Set Digital input 2 as enabling input of the PD block of the PID
Digital input 2 = Enable PD PID

parameters

Program Speed base value equal to the rated speed of the motor.
Speed base value = 3000rpm

Program PID source as PAD 0.
(PAD 0 has been used as supporting parameter of the feed-forward reading on Analog input 2)
For PID source set the parameter number to which it will be associated, choosing it from the list of paragraph

10.4. “List of high-priority parameters’ (PAD 0 has the decimal number 503).
To obtain the correct value it must be added the decimal number 8192 (fixed offset):
PID source = (8192 + 503) = 8695

Set PID source Gain so that Feed-fwd PID reaches, along with the max. analog value on Analog input 2, 85%

of its max. value = 10000 x 85%.
When an analog input is set on a PAD parameter , this will have a max. value +/- 2047.

So:
PID source Gain = (max Feed-fwd PID x 85%) / max PAD 0 = (10000 x 0.85) / 2047 = 4.153

Set PID target as Speed ref 1.

n

ote

:

When the ramp function is enabled, Speed ref 1 is not available. In order to have it available,

it is necessary to set the parameter Enable ramp = Disable.

For PID target set the parameter number to which it will be associated, choosing it from the list of paragraph

10.4 “List of high-priority parameters’ (Speed ref 1 has the decimal number 42).