——— PARAMETER LISTS ———
10
29
Parameter
No.
Format
Value
Access via
min
max
Factory
American
Factory
European
Keyp.
RS485/
BUS/
Opt2-M
Term.
Opt2-A/
PDC
Gen amplitude [%]
60
Float
0
200.00
0
0
ü
R/W
-
-
Generator offset [%]
61
Float
-200.00 +200.00
0
0
ü
R/W
-
-
SPEC FUNCTIONS
Save parameters
256
U16
ü
C/W(1)
-
-
Load default
258
U16
ü
Z/C(1)
-
-
Life time [h.min]
235
Float
0.00
65535.00
ü
R
-
-
Failure register
330
U16
1
10
10
10
ü
R/W
-
-
Failure text
327
Text
-
R
-
-
Failure hour
328
U16
0
65535
R
-
-
Failure minute
329
U16
0
59
R
-
-
Failure code
Failure supply
Undervoltage
Overvoltage
Overcurrent
Heatsink
Hardware
DSP error
Interrupt error
Speed fbk
External fault
Overtemp motor
Field loss
Bus loss
Hw opt 1 failure
Opt2
Unknown
Enable seq err
417
U16
0
65535
R
5100h
3120h
3310h
2300h
4210h
5000h
6110h
6120h
7301h
9000h
4310h
3330h
8110h
7510h
7400h
1001h
9009h
-
-
Failure reset
262
U16
ü
Z/C (1) ID (H)
W
Failure reg del
263
U16
ü
C
-
-
SPEC FUNCTIONS \ Links \ Link 1
Source
484
U16
0
65535
0
0
ü
R/W
-
-
Destination
485
U16
0
65535
0
0
ü
R/W
-
-
Mul gain
486
Float
-10000
+10000
1
1
ü
R/W
-
-
Div gain
487
Float
-10000
+10000
1
1
ü
R/W
-
-
Input max
488
Float
-231
231-1
0
0
ü
R/W
-
-
Input min
489
Float
-231
231-1
0
0
ü
R/W
-
-
Input offset
490
Float
-231
231-1
0
0
ü
R/W
-
-
Output offset
491
Float
-231
231-1
0
0
ü
R/W
-
-
Inp absolute
OFF
ON
492
U16
0
1
OFF
OFF
ü
R/W
0
1
-
-
SPEC FUNCTIONS \ Links \ Link 2
Source
553
U16
0
65535
0
0
ü
R/W
-
-
Destination
554
U16
0
65535
0
0
ü
R/W
-
-
Mul gain
555
Float
-10000
+10000
1
1
ü
R/W
-
-
Div gain
556
Float
-10000
+10000
1
1
ü
R/W
-
-
Input max
557
Float
-231
231-1
0
0
ü
R/W
-
-
Input min
558
Float
-231
231-1
0
0
ü
R/W
-
-
Input offset
559
Float
-231
231-1
0
0
ü
R/W
-
-
Output offset
560
Float
-231
231-1
0
0
ü
R/W
-
-
Inp absolute
OFF
ON
561
U16
0
1
OFF
OFF
ü
R/W
0
1
-
-