Figure 6.4.2.1: speed reference, 19 n, Speed base value cannot exceed 8192 rpm – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 147: Speed ref 1 [ff] speed ref 1 (%), Speed ref 2 [ff] speed ref 2 (%), Speed ref (rpm) speed ref (d) [ff] speed ref (%)

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

19

n

ote

!

Two quadrant 6KDV3 ... Q2 drives accept only positive references. Negative values are not

considered!

-

+

Speed Regulator

DV_SReg

DV_Ovr_RfSel

From Speed

Reference

generation

DV_Droop_cp

+

+

+

-

+

T

DV_MotPar

To Motor Control

DV_Curr_reg

Current Regulator

+

+

MAX Speed Limits

DV_Spd_Fbk

Encoder 2

Encoder 1

Actual speed

Output voltage

Droop compensation

Speed Feedback

Droop gain

0 %

Speed max amount

1750 rpm

Speed max pos

1750 rpm

Speed max neg

1750 rpm

Speed ref 2

0 rpm

Speed reg output

Enable spd reg

T current ref 1

0 %

T current ref 2

0 %

T current ref

Load comp

0 %

Spd draw out (d)

Speed ref (d)

Actual spd (d)

T current ref

Speed limited

Motor current

Speed fbk sel

Encoder 1

Enc 1 speed

Speed fbk sel

Encoder 2

Enc 2 speed

Speed fbk sel

Tacho

Actual spd (d)

Speed fbk sel

Armature

Output voltage

Figure 6.4.2.1: Speed reference

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed ref 1 [FF]

Speed ref 1 (%)

42

378

-2 P45

-200.0

+2 P45

+200.0

0

0.0

0

0.0

Ramp output *

Speed ref 2 [FF]

Speed Ref 2 (%)

43

379

-2 P45

-200.0

+2 P45

+200.0

0

0.0

0

0.0

*

Speed ref (rpm)

Speed ref (d) [FF]

Speed ref (%)

118

115

117

-32768

-32768

-32768

+32767

+32767

-200.0

-

-

+200.0

-

-

-

**

* This function can be assigned to one of the programmable analog inputs.
** This parameter can be assigned to a programmable analog output.

Speed ref 1

1st reference value for the speed. The value to be entered depends on the factor function.

Speed ref 1 (%)

1st speed reference value as a percentage of the Speed base value

Speed ref 2

2nd reference value for the speed. The value to be entered depends on the factor function.

Speed ref 2 (%)

2nd speed reference value as a percentage of the Speed base value

Speed ref (rpm)

Total speed reference value in rpm.

Speed ref (d)

Total speed reference value in the dimension specified by the factor function.

Speed ref (%)

Total speed reference value as a percentage of the Speed base value.

n

ota

:

Speed base value cannot exceed 8192 rpm

Advertising