Final operation, Tuning, Current self tuning – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 139: Speed self tune

Advertising
background image

DV-300 Adjustable Speed Drives

——— FUNCTION DESCRIPTION ———

6

11

Final operation

(See chapter 6.11.1 for more parameters detail).

Main commands

This command specifies from where the Enable drive and Start command has to be

actuated.

Control mode

Defines whether the digital channel is the keypad/RS485 or Fieldbus card.

Save parameters

Saving of user parameters value setting

TuNING

This menu allows a fine manual tuning of the drive regulators.

Current self tuning

Current regulator self tuning procedure via R&L Search (as indicate in START UP menu).

Speed self tune

Speed regulator self tune procedure (as indicate in START UP\ Speed self tune menu).

Manual tuning of speed regulator, field regulator and voltage regulator

Manual tuning of the drive regulators (see chaper 5.3.6 for other details) :

Speed P

Proportional coefficient of the speed regulator in percentage

Speed I

Integral coefficient of the speed regulator in percentage.

Prop filter

Time constant filter to the proportional coefficient of the speed regulator

Flux P

Proportional coefficient of the field regulator in percentage.

Flux I

Integral coefficient of the field regulator in percentage

Voltage P

Proportional coefficient of the voltage regulator in percentage.

Voltage I

Integral coefficient of the voltage regulator in percentage

Save parameters

Saving of user parameters value setting