2.4.5 Accuracy

Internal reference voltage (± 10V, terminals 7 and 8):

temperature dependent stability error

100 ppm/°C

References

via keypad/serial line/Bus

resolution:

16 Bit or 15 Bit + sign

via terminals (1/2, 3/4, 5/6)

resolution:

11 Bit + sign

linearity

±0.1% of the full range value

Analog outputs (6KCV300TBO only)

resolution:

11 Bit + sign

linearity:

±0.5% of the full range value

Speed regulation

for all the operation mode

max speed

8000 rpm

digital reference resolution:

0.25 rpm

analog reference resolution:

0.25 rpm

with sinusoidal encoder

speed feedback resolution:

0.25 rpm

accuracy

typical 0.01%

control range

better than 1:10000

with digital encoder

speed feedback resolution

0.5 rpm

accuracy

typical 0.02%

control range

better than 1:1000

with tachogenerator

speed feedback resolution

better than 1:2000

accuracy

typical 0.1%

control range

better than 1:1000

Torque regulation

resolution

better than 1:2000

accuracy

typical 0.2%

control range

better than 1:500