GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 420

Advertising
background image

GEI-100332Ga

——— PARAMETER LISTS ———

10

26

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

FUNCTIONS \ Motor pot

Enable motor pot

Enabled

Disabled

246

I16

0

1

Disabled

Disabled

ü

R/Z

1

0

-

-

Motor pot oper

247

ü

-

-

-

Motor pot sign

Positive

Negative

248

I16

0

1

Positive

Positive

ü

R/W

1

0

ID

-

Motor pot reset

249

U16

ü

Z/C(1)

ID (H)

-

Motor pot up

No acceleration

Acceleration

396

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Motor pot down

No deceleration

Deceleration

397

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

FUNCTIONS \ Jog function

Enable jog

Enabled

Disabled

244

I16

0

1

Disabled

Disabled

ü

R/Z

1

0

-

-

Jog operation

265

-

-

-

-

-

ü

-

-

-

Jog selection

Speed input

Ramp input

375

U16

0

1

0

0

ü

R/Z

0

1

-

-

Jog reference [FF]

266

I16

0

32767

0

0

ü

R/W

IA

-

Jog +

No jog forwards

Forwards jog

398

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

Jog -

No backwards jog

Backwards jog

399

U16

0

1

R/W

0

1

ID

L

H

R/W

0

1

FUNCTIONS \ Multi speed fct

Enab multi spd

Enabled

Disabled

153

I16

0

1

Disabled

Disabled

ü

R/Z

1

0

-

-

Multi speed 1 [FF]

154

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 2 [FF]

155

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 3 [FF]

156

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 4 [FF]

157

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 5 [FF]

158

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 6 [FF]

159

I16

-32768

+32767

0

0

ü

R/W

-

-

Multi speed 7 [FF]

160

I16

-32768

+32767

0

0

ü

R/W

-

-

Speed sel 0

Value 2

0

not selected

Value 2

0

selected

400

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Speed sel 1

Value 2

1

not selected

Value 2

1

selected

401

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Speed sel 2

Value 2

2

not selected

Value 2

2

selected

402

U16

0

1

0

0

-

R/W

0

1

ID

L

H

R/W

0

1

Multispeed sel

208

U16

0

7

0

0

ü

R/W

ID

R/W

FUNCTIONS \ Multi ramp fct

Enab multi rmp

Enabled

Disabled

243

I16

0

1

Disabled

Disabled

ü

R/Z

1

0

-

-

Ramp selector

202

U16

0

3

0

0

ü

R/W

ID

R/W

Advertising