148

PD control

[768]

PD P gain 1 PID [%]

[766]

PD D gain 1 PID [%]

[788]

PD P gain 2 PID [%]

[789]

PD D gain 2 PID [%]

[790]

PD P gain 3 PID [%]

[791]

PD D gain 3 PID[%]

[767]

PD D filter PID [ms]

[421]

PD output PID

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

PD P gain 1 PID [%]

768

0.00

100.00

10.00

10.00

PD D gain 1 PID [%]

766

0.00

100.00

1.00

1.00

PD P gain 2 PID [%]

788

0.00

100.00

10.00

10.00

PD D gain 2 PID [%]

789

0.00

100.00

1.00

1.00

PD P gain 3 PID [%]

790

0.00

100.00

10.00

10.00

PD D gain 3 PID[%]

791

0.00

100.00

1.00

1.00

PD D filter PID [ms]

767

0

1000

0

0

PD output PID

421

-10000

+10000

0

0

The gains of the block can remain fixed and programmed in this case through the parameters PD P gain 1 PID

and PD I gain 1 PID, or changed depending on machine parameters, through the function Adap spd reg. In this

case the gains come from PD P gain 1-2-3 PID and PD I gain 1-2-3 PID.
For example, it is possible to modify, dynamically, the gains of PD block according to the speed, to a regula-

tion parameter internal to the drive, or to an analog input proportional to the unit related to the machine. The

behaviour of the regulator can be so configured to meet the needs of the machine.

n

ote

:

When Adap Spd reg has been enabled (paragraph 6.13.2. of the manual), it operates both on

the PID function and on the gains of the speed regulator. So it is necessary to appropriately

program all relative parameters. If one wishes to modify only the gains of the speed regulator

and keep fixed the gains of the PID function, it is necessary set the three proportional gains

and integral gains of the PD block at the same value. The same is valid in case the PID gains

have to be modified and the speed regulator gains must remain fixed.

PD P gain 1

Proportional gain 1 of the block PD (its selection depends on the eventual enabling of

the function Adap Spd reg and its configuration).

PD D gain 1

Derivative gain 1 of block PD (its selection depends on the eventual enabling of the

function Adap Spd reg and its configuration).

PD P gain 2

Proportional gain 2 of the block PD (its selection depends on the eventual enabling of

the function Adap Spd reg and its configuration).

PD D gain 2

Derivative gain 2 of block PD (its selection depends on the eventual enabling of the

function Adap Spd reg and its configuration).

PD P gain 3

Proportional gain 3 of the block PD (its selection depends on the eventual enabling of

the function Adap Spd reg and its configuration).

PD D gain 3

Derivative gain 3 of block PD (its selection depends on the eventual enabling of the

function Adap Spd reg and its configuration).

PD D filter PID

Time constant of the filter from the derivative side.

PD output PID

PD block output.

Advertising