GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 208

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

80

The function “Tach follower” can be used in accordance with the tabe below:

Speed fbk sel [414]

Encoder 1 as reference

Encoder 2 as reference

Encoder 1

Not available

Not available

Encoder 2

Available

Not available

Tacho

Not available

Available

Armature

Available

Available

DV0727g

n

ote

!

It is possible to set any configuration. Follow the configuration possible in the table above.

Select enc 1

These parameters define which speed reference the encoder signal will reference to.

Select enc 2

The OFF condition indicates that the encoder connector is not used as speed reference and

then it could be used as speed feedback. (CONFIGURATION/Speed fbk sel menu).

The speed reference destination choice must be done according to the speed regulator

configuration (e.g. can not use Speed ref 1 with the ramp active).

Encoder 1 type

It defines the encoder type to the XE1 connector connected.

Sinusoidal

Sinusoidal encoder

Digital

Digital encoder (DES option required)

Encoder 1 pulses

Pulse number of the encoder to the XE1 connector connected.

Encoder 2 pulses

Pulse number of the encoder to the XE2 connector connected.

Refresh enc 1

Enables the monitoring of the encoder 1 connection status, in order to detect a speed

feedback loss alarm

Refresh enc 2

Enables the monitoring of the digital encoder 2 connection status, in order to detect a

speed feedback loss alarm

XE1

XE2

M

E

EXT REF

Drive A

(Master)

Encoder 2

XE1

XE2

M

E

Drive B

(Follower)

XE1

XE2

M

Drive C

(Follower)

Spd fbk sel

Tacho

DES

(option)

Enc 1 REF

Enc 2 REF

Enc 2

Fbk

Enc 2

Fbk

Digital encoder

Digital encoder

+

Analog
input 1

(1)

(2)

(3)

(4)

(5)

Spd fbk sel

Spd fbk sel

Encoder 2

(1) Analog inputs/ Select input 1 = Ramp ref 1

(4) Speed fbk sel = Encoder 2

(2) Speed fbk sel = Encoder 2

(5) Select enc 2 = Ramp ref 1

(3) Select enc 1 = Ramp ref 1

Figure 6.12.5.2: Example of application of the encoder reference

The Drive A speed reference is provided in this case by an external analog signal but it could be set from internal

digital sources (e.g. DGF optional card or field bus).
A configuration using the encoder signal as the line speed reference, is only possible when the speed reference

source is provided by an additional encoder, independent from the motor shaft.

Advertising