Figure 6.17.4: functioning with jog tw enable – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 318

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

190

Status 6:

The system reaches this status when the parameter Jog TW enable is enabled and the Start command has

been given. The Jog command is used on unwinders in order to bring the coil material till the first nip roll.

See figure 6.17.4.

Status 1

(default)

Status 6

Jog T W enable = 1

Start (drive) = 1

Jog T W enable = 1

Start (drive) = 0

Int acc time = Spd match acc

Int dec time = Spd match dec

W reference = f (Jog T W speed,

)

Int acc time = Spd match acc

Int dec time = Spd match dec

W reference = 0

Figure 6.17.4: Functioning with Jog TW enable

Jog TW enable prepares the system for a particular functioning condition; in order to enable the coil rotation

it is necessary to give the Start command, a following Stop will force the speed reference to 0 (see paragraph

Control logic).

In the Status 6 the motor speed reference is set to:

W reference = Jog TW speed x Minimum diameter ÷ Roll diameter

It is possible to change the Jog speed sign by using the command Winder side.

If starting from the Status 6, Jog TW enable is disabled by keeping the Start command, the system switches

to the Status 2.