GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 432

Advertising
background image

GEI-100332Ga

——— PARAMETER LISTS ———

10

38

Parameter

No.

Format

Value

Access via

min

max

Factory

American

Factory

European

Keyp.

RS485/

BUS/

Opt2-M

Term.

Opt2-A/

PDC

Ramp ref 2 [FF]

48

I16

-2 P45 +2 P45

0

0

ü

R/W

IA, QA

R/W

Ramp ref 2 (%)

49

Float

-200.0

+200.0

0.0

0.0

ü

R/W

-

-

Dim factor num

50

I32***

1

65535

1

1

ü

R/Z

-

R

Dim factor den

51

I32***

1

231-1

1

1

ü

R/Z

-

R

Dim factor text

52

Text

rpm

rpm

ü

R/Z

-

-

Face value den

53

I16

1

32767

1

1

ü

R/Z

-

R

Face value num

54

I16

1

+32767

1

1

ü

R/Z

-

R

Control word

55

U16

0

65535

ü

R/W

-

R/W

Status word

56

U16

0

65535

ü

R

-

R

Malfunction code

Failure supply

Undervoltage

Overvoltage

Overcurrent

Heatsink

Hardware

DSP error

Interrupt error

Speed fbk loss

External fault

Overtemp motor

Field loss

Bus loss

Hw opt 1 failure

Opt2

Unknown

Enable seq err

57

I16

ü

5100h

3120h

3310h

2300h

4210h

5000h

6110h

6120h

7301h

9000h

4310h

3330h

8110h

7510h

7400h

1001h

9009h

R

5100h

3120h

3310h

2300h

4210h

5000h

6110h

6120h

7301h

9000h

4310h

3330h

8110h

7510h

7400h

1001h

9009h

-

-

Generator access

Not connected

T current ref

Flux ref

Ramp ref

Speed ref

58

U16

0

5

Not conn. Not conn.

ü

R/Z

0

2

3

4

5

-

-

Gen frequency [Hz]

59

Float

0.1

62.5

0.1

0.1

ü

R/W

-

-

Gen amplitude [%]

60

Float

0

200.00

0

0

ü

R/W

-

-

Generator offset [%]

61

Float

-200.00 +200.00

0

0

ü

R/W

-

-

Scale output 1

62

Float

-10.000 +10.000

0.000

0.000

ü

R/W

-

Scale output 2

63

Float

-10.000

+10000

0.000

0.000

ü

R/W

-

-

Scale output 3

64

Float

-10.000

+10000

0.000

0.000

ü

R/W

-

-

Scale output 4

65

Float

-10.000

+10000

0.000

0.000

ü

R/W

-

-

Advertising