Speed-up function, Setting of the speed zero logic, Speed-up function setting of the speed zero logic – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 127: Function speed-up is not active

Advertising
background image

DV-300 Adjustable Speed Drives

——— CONVERTER OPERATION ———

5

51

Carry out the reading of the current circulating in the Flux current parameter (FLUX REGULATION menu)

and insert it in the I field cnst 40 parameter (FLUX REGULATION\Flux if curve menu).

- Disable the converter
- Via the Set flux / if parameter (FLUX REGULATION menu) the calculation of the curve parameters will

be carried out. Enter this parameter then press ENT to execute the calculation.

The procedure requires a few seconds.

- Set the operating mode of the field control (Constant current / Voltage control), set the value of Flux

current max at 100% and save the parameters.

- Changing of Max out voltage or Motor nom flux need a new curve tuning.

Speed-up function

With loads having a high moment of inertia it is possible to check the jumps during the speed changes. They can

be reduced using the function “Speed-up”. The figures 5.3.7.3 and 5.3.7.4 show the influence of this function

Parameters used in the example:

Speed up base

14 ms

Speed up gain

50 %

Speed up filter

20 ms

Setting of the speed zero logic

- The speed zero logic is factory set as disabled. See section 6.7.2, “Speed zero logic”, for a description of

the drive behavior.

- Disable of the I-section of the speed regulator with n=0:

I-section disabled:

Enable spd=0 I = Enabled

I-section enabled:

Enable spd=0 I = Disabled

n

ote

!

When the motor is at a stop, it is possible to avoid the creep of the drive disabling the I sec-

tion. In this case when the motor is at a stop, it can not receive any load and therefore this

function is not suitable for all applications!

Figure 5.3.7.3: Above: Actual spd; Below: Motor cur-

rent jumps with the speed changes due to a high mo-

ment of inertia. The function Speed-up is not active.

Figure 5.3.7.4: Above: Actual spd; Below: Motor

current. The same drive with Speed -up function

active.

Advertising