2 ­speed, 2 speed – GE Industrial Solutions DV-300 DC Drive Users Manual User Manual

Page 344

Advertising
background image

GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

216

6.18.2 Speed

DRIVECOM

[44]

Speed input var [FF]

[115]

Speed ref var [FF]

[119]

Act speed value [FF]

[45]

Speed base value [FF]

[46]

Speed input perc [%]

[116]

Percent ref var [%]

[120]

Act percentage [%]

Parameter description

No.

Value

Standard

Configuration

min

max

Factory

American

Factory

European

Speed input var [FF]

44

-2 P45 +2 P45

0

0

*

Speed ref var [FF]

115

-32768

+32767

-

-

**

Act speed value [FF]

119

-32768

+32767

-

-

***

Speed base value [FF]

45

1

16383

1500

1500

Speed input perc [%]

46

-32768

+32767

0

0

*

Percent ref var [%]

116

-32768

+32767

**

Act percentage [%]

120

-32768

+32767

***

* Factory set as Ramp ref and connected to analog input 1 (terminal 1 and 2). See reference values.

** Factory set as Speed ref and connected to the ramp output. See reference values.

*** Factory set as Motor speed and connected to analog output 1. See BASIC MENU.

Speed input var

1st ramp reference value. The value to be entered is based on the factor function

Speed ref var

1st speed reference value. The value to be entered is based on the factor function

Act speed value

Speed actual value in the unit specified in the factor function.

Speed base value

The Speed base value is given in the unit specified in the factor function. It is the

base value for all speed values given as a percentage (reference values, adaptive speed

regulation ...). A change in this parameter is only possible when the drive is disabled.

(Enable drive = Disabled).

Speed input perc

1st ramp reference value. Defined as a percentage of the Speed base value

Percent ref var

1st speed reference value. Defined as a percentage of the Speed base value

Act percentage

Speed actual value as a percentage of the Speed base value