GEI-100332Ga

——— FUNCTION DESCRIPTION ———

6

90

15 11

12 13

14

DRIVE

19

18

+24V

0V

24

Digital

input

1

Digital

input

2

Digital

input

3

Digital

input

4

COM D I/O

Jog

+

Jog

-

+

-

Speed Regulator

Ramp ref (rpm)

F

F

Ramp

Speed limits

Speed ref 1 (%)

Jog -

No Backward Jog

Jog +

No Forward Jog

Start/Stop

Stop drive

Enable jog

Enabled

Jog selection

Speed Input

Speed ref 1

0 rpm

Jog reference

100 rpm

Speed ref 2

0 rpm

Start/Stop

Stop drive

Enable jog

Enabled

Jog selection

Speed Input

Speed ref

Speed ref (d)

Speed ref (%)

Speed ref (d)

Percent ref var

Speed ref 2

%

Figure 6.14.2.1: Example of external activation in Jog mode

n

ote

!

The following signals are required for Jog mode in addition to the commands Jog + and Jog - :

Enable drive

Fast Stop

External fault

Low Disabled

The jog speed corresponds to the value which is defined by the Jog reference parameter. In this case no ramp is

used.
The jog reference value can only be activated by the Jog + or Jog - command if there is no Start command active.
If the Start command is given in addition to the Jog + and Jog - command, Jog mode will be aborted and the

drive will react according to the Start command.
When controlled via the keypad the “+” and “-” keys can be used in the Jog function menu. (only for 6KDV3...

Q4...). For this select the Jog operation menu point.
The correction value Speed ref 2 for the speed regulator is also active in jog operation.

n

ote

!

If the Stop control function is activated, to enable the Jog function the Jog Stop control

(FUNCTION/Stop control) must also be set to ON (1).